RECOMMENDATIONS:
Make sure you comply with national
regulations when you dispose of your
product at end-of-life. Please dispose of this
product at a location designed for this
purpose in order to ensure the protection of
the environment.
CLASS II MAINS POWER
Reference: MN0151-E050300
f
f
AC 100-240V - 50/60Hz - 0,5A
f
f
3A
Only use the mains power unit supplied with the
device. Please replace this unit should it fail (contact
SPORT-ELEC®, or order at www.sport-elec.com).
ELECTRODE DATA:
Class I medical device (directive 93/42/EEC) - Adhesive,
hydrophilic and hypoallergenic electrodes
Reference
. . . . . . . . . . . . . . . . .
Contact surface
. . . . . .
Estimated life cycle
Do not hesitate to order FREE ACTION adhesive
electrodes at www.sport-elec.com.
If the problem persists after carrying out the following checks,
contact our After-sales service at +33 2 32 96 50 51 or sav@sport-elec.com
MOTOR LED FLASHES RED
Charge (see chapter III) and retry.
f
f
TRIANGLE SYMBOL
or MOTOR LED FLASHES WHITE
Turn all terminals (remote control + motors) OFF
f
f
and ON again
If the problem persists, contact the after-sales
f
f
service directly
WHITE BARGRAPH
The electrode in question is disconnected.
Try new electrodes.
f
f
Check the contact between the electrode
f
f
and the skin.
Check that the motor is fixed to the electrode.
f
f
Check that the motor is ON.
f
f
Then try to increase power again.
f
f
ONE OR SEVERAL TERMINALS FAIL TO COME
ON OR EXPECTEDLY TURN OFF
Charge all of the terminals for ~2 hours.
f
f
Restart your terminals.
f
f
Restart the preferred program.
f
f
24
DC 5V
EASF110X71 - EAEXP100X50
67,5x47mm (x2) - 100x50mm (x2)
40 usages
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
XII. SOLVING PROBLEMS
TERMINAL DATA:
Current type
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Number of programs
14 (8 "SPORT" + 6 "HEALTH")
. . . . . . . . .
Number of program variations (or phases)
Number of adjustable independent channels:
Maximum intensity per channel up to 1kΩ
Frequency range
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pulse range
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.7V - 1020 mAh (remote control)
Remote control dimensions
. . . . . . . . . . . .
Remote control weight
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Motor dimensions
. . . . . . . . . . . . . . . . . . . . . . . . . . .
Motor weight
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Contact sensor
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
(channel power gauge > white)
Automatic stop at the end of each session
Start safety
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Classification
BF type: device in contact with the
. . .
patient, excluding the heart muscles.
RoHS
Devices are constructed without materials with a
.
potential harmful impact on the environment.
EC declaration of conformity.
I CAN'T FEEL ANY MUSCLE CONTRACTIONS
Try new electrodes.
f
f
Check that the electrodes are in contact with
f
f
the skin.
Check that the motors are fixed to the electrodes.
f
f
Check the connection between the motors and
f
f
the remote control ("info"
check"
touchscreen icons)
Check that a program is indeed in progress (e.g.
f
f
the "introductory" program
Try to increase the power (see chapter VIII)
f
f
If you have several FREE ACTION devices, check
f
f
that you are using the remote control for the
motors in question.
ALL GREYED OUT EXCEPT
"PARAMETERS"
Align motors
(see chapter V. )
two-phase
255
. . . . . . . . . . . . .
up to 4
. . .
90mA
. .
0.5-120 Hz
70-360 μs
Rechargeable LiPo battery
3.7V - 420 mAh (motors)
79 x 135 x 24 mm
146 g
78 x 52 x 20 mm
51 g
Yes
Yes
. . . . . . . . . . . . .
Yes: Autotest
or "motor state
, see chapter VII).