Storage
8
Storage
Store the ventilation vest dry and free from dust and contamination. Keep out of
UV light and direct sunlight; avoid ozone and large temperature fluctuations.
Observe the permitted storage temperature. Route the hoses so that the bending
radius is not too small and the hoses are not under tension or pressure or twisted.
9
Disposal
Dispose of the ventilation vest in accordance with the applicable rules and
regulations.
10

Technical data

Weight
Vest and
connecting hose
Air line breathing apparatus
Sound pressure level in the suit
Sound pressure level of the warning
whistle
Whistling sound activation
Temperatures:
in usage
in storage
Air line breathing apparatus
Inlet pressure
Inlet coupling
Minimum inlet air flow
Maximum outlet flow approx.
20
<1.4 kg
<0.5 kg
<70 dB(A)
>90 dB(A)
If the pressure falls below 2.5 ±0.5 bar
+10°C to +60°C
(in combination with the chemical
protective suit)
-20 °C to +40 °C
3.0 bar to 10 bar
CEJN 96/series Rectus 346
(other clutches available from Dräger)
300 L/min
380 L/min
11
Order list
Description
Dräger CVA 0700 complete (3363504 and 3363603)
Dräger X-plore 9310 (with waist belt)
Dräger CVA 0700 (vest and connection hose only)
Chest strap extension (25 cm, 10 pieces)
Inner vest spare part set CVA 0700
Silencer spare part set
Order number
3363602
3363504
3363603
3700041
3364751
3700517