Reset Function - Beretta EXCLUSIVE 25R Para El Instalador

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 39
EXCLUSIVE
- select from among the following options: REMOVE WATER TANK and
TANK TYPE.
REMOVE WATER TANK
TANK FLOW TEMP
INSTALLER
TYPE OF WATER TANK
This parameter allows you to set the type of domestic water tank. Set the
value to 1 to select a water tank with probe, set the value to 0 to select a
water tank with thermostat (factory setting).
REMOVE WATER TANK
This function is used to disable the operation of the domestic water tank;
water tank disabled, the relative configuration menu is no longer accessible.
If you want to add a water tank again, after previously removing it, follow
the instructions below:
- access the technical parameters as explained in the section "4.1 Access
to the technical parameters"
- select ADD HW TANK with the "up" and "down" keys, confirming the
selection
COMBUSTION ANALYSIS
EXHAUST PROBE RESET
INSTALLER
Then complete the configuration of the water tank referring to the specific
section.
b
After adding the water tank, DOMESTIC HOT WATER is displayed
on the "Programme" page. This function allows the domestic hot
water programming timing to be carried out.
WATER TANK DELIVERY
b
The parameter allows you to set the delivery temperature of the
boiler when the SLIDING DELIVERY function is not active. The
factory setting is 80°C.
5.8
Boiler start-up
If there is a room thermostat or a programming timer, or the REC10
MASTER is set as an ambient regulator, it is necessary that these are on
and that they have been adjusted to a temperature higher than the ambient
temperature so that the boiler switches on.
The boiler will be in standby until the burner switches on following a heat
request. The display shows "
FRI
FRI
18/05/2013
MENU
MENU
INFO
INFO
HOT WATER TEMPERATURE
HOT WATER TEMPERATURE
The boiler will be in function until the selected temperature is reached,
afterwards it will be in "standby" again keeping the outlet temperature displayed.
If faults arise in ignition or operations, the boiler performs a "SAFETY STOP":
the triangle signalling faults will flash on the REC10. To identify the fault codes
and to reset the boiler, see the section "5.15 Lights and faults" .
20
HW TANK
TANK TYPE
TECHNICAL
RANGE RATED
CALIBRATION
ADD HW TANK
" to indicate the presence of a flame.
PLANT
PLANT
12:17
1.3 bar
STATE
STATE
42
°C
SET
SET
FLAME LOCKOUT
FLAME LOCKOUT
PRESS OK TO RESET
PRESS OK RESET
5.9

Reset function

In the event of a lockout, it is possible to try and restore the normal operation
of the appliance by pressing the key "ok" on the REC10 when the fault
message is displayed for resetting the alarm in progress.
b
If the release attempts do not restart the boiler, contact the local
Technical Assistance Centre.
5.10 Screed heating function
For low temperature system the boiler has a "screed heating" function that
can be activated in the following way:
- set the status of the boiler to OFF
HOT WATER ONLY
HEATING AND HOT WATER
- access the technical parameters as explained in the section "4.1 Access
to the technical parameters"
- select SCREED HEATING with the "up" and "down" keys, confirming
the selection (note: SCREED HEATING is not available if the boiler is
not OFF)
RANGE RATED
CALIBRATION
COMBUSTION ANALYSIS
EXHAUST PROBE RESET
EXHAUST PROBE RESET
SCREED HEATING
SCREED HEATING
INSTALLER
INSTALLER
- select ACTIVATE FUNCTION with the "up" and "down" keys and
confirm the selection to activate the function
- select DEACTIVATE FUNCTION with the "up" and "down" keys and
confirm the selection to deactivate the function.
SCREED HEATING
SCREED HEATING
DEACTIVATE FUNCTION
DEACTIVATE FUNCTION
FUNZIONE GIORNALIERA
ACTIVATE FUNCTION
ACTIVATE FUNCTION
INSTALLER
INSTALLER
The screed heating function, when active, is signalled on the main
screen by the scrolling message at the bottom of the SCREED HEATING
FUNCTION IN PROGRESS - OUTLET TEMPERATURE, while on the
electronic board the red and green LEDs flash alternately with a frequency
of 1 sec ON - 1 sec OFF.
The "screed heating" function lasts 168 hours (7 days) during which, in
the zones configured as low temperature, a heating request is simulated
with an initial zone outlet of 20°C, then increased in line with the table on
the side.
E010
BOILER
BOILER
OFF
OFF
SUMMER
WINTER
TECHNICAL
TECHNICAL
RANGE RATED
CALIBRATION
SWEEPER

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Exclusive 35rExclusive 42r

Tabla de contenido