8 TECHNICAL SPECIFICATIONS
Power supply voltage U1 (50/60Hz)
Slow blow line fuse
Maximum input power (kVA)
Maximum input power (kW)
Power factor PF
Efficiency (μ)
Max. input current I1max
Effective current I1eff
Duty factor (40°C)
(x=50%)
(x=60%)
(x=100%)
Duty factor (25°C)
(x=100%)
Adjustment range I2
Open circuit voltage Uo
IP Protection rating
Insulation class
Dimensions (lxdxh)
Weight
Power supply cable
Manufacturing Standards
All manuals and user guides at all-guides.com
GENESIS 284 PSR
3x400 Vac ±15%
25 A
14,5 KVA
10,0 Kw
0,69
0,87
21 A
16,2 A
-
280 A
220 A
280 A
6-280 A
81 Vdc
IP23S
H
620x280x500 mm
34 Kg.
4x6 mm 2
EN 60974-1
EN 60974-3
EN 60974-10
GENESIS 354 PSR
GENESIS 504 PSR
3x400 Vac ±15%
3x400 Vac ±15%
30 A
40 A
19 KVA
29,8 KVA
13,7 Kw
23 Kw
0,72
0,77
0,87
0,87
27,5 A
43 A
21,3 A
33 A
-
500 A
350 A
460 A
270 A
400 A
350 A
500 A
6-350 A
6-500 A
81 Vdc
79 Vdc
IP23S
IP23S
H
H
620x280x500 mm
620x280x500 mm
34 Kg.
42 Kg.
4x6 mm 2
4x6 mm 2
EN 60974-1
EN 60974-1
EN 60974-3
EN 60974-3
EN 60974-10
EN 60974-10
49