System Presentation; General; Front Control Panel - Selco Genesis 284 PSR Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 103
Connection for TIG welding
- Connect (1) the earth clamp to the positive socket (+) (2)
ofthe power source.
- Connect the TIG torch coupling (3) to the torch socket (4)
ofthe power source.
- Connect the gas hose from the cylinder to the rear gas con-
nection.
System for shipbuilding industry
- Connect the power cable to the appropriate outlet (1).
- Connect the signal cable to the appropriate connector (2).
Insert the connector and screw the ring nut clockwise until all
parts are secured.
- Connect the gas hose to the pressure reducing valve of the
cylinder or to the gas supply connection.
- Connect the water pipe (blue colored
quick connector of the cooling unit (3).
- Connect the water pipe (red colored
connector of the cooling unit (4).
All manuals and user guides at all-guides.com
) to the outlet
) to the inlet quick
Weld@net system

3 SYSTEM PRESENTATION

3.1 General

The Genesis 284-354-504 PSR are constant current inverter power
sources developed for electrode (MMA), TIG DC (direct current).
They are fully digital multiprocessor systems (data processing on
DSP and communication over CAN-BUS), capable of meeting
the various requirements of the welding world in the best pos-
sible way.
The RC 300 remote control constitutes the programming panel
of a PSR series welding system. It is not an accessory but instead
is an essential component for the operation of the equipment.
It allows:
- selection of the welding process
- setting and correction of the welding parameters
- the storage and retrieval of tailor-made programs
- setting of the guard limits
- display of the real current, voltage, gas measurements...
- display of the alarm signals

3.2 Front control panel

1
Power supply
Indicates that the equipment is connected to the mains
and is on.
2
General alarm
Indicates the possible intervention of protection devices
such as the temperature protection.
3
Power on
Indicates the presence of voltage on the equipment
outlet connections.
4
Signal cable (CAN-BUS) input
Allows connection of the external devices such as RC, RI....
Allows digital communication (CAN-BUS) between the
generator and the connected device.
33

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Genesis 354 psrGenesis 504 psr

Tabla de contenido