3. Ceiling Fan Assembly
3.9
The Fan comes with Black and White Leads that are
80" long.
Measure up approximately 6 to 9-inches above top of
Hanger Ball / 6" Downrod Assembly (Figure 9).
Cut off excess Leads and strip back Insulation 1/2-inch
from end of Leads.
WARNING
!
The fan must be hung with at least 7' of clearance from
floor to blades (Figure 10).
WARNING
!
Turning off wall switch is not sufficient. To avoid possible
electrical shock, be sure electricity is turned off at the
main fuse box before wiring. All wiring must be in
accordance with National and Local codes and the ceiling
fan must be properly grounded as a precaution against
possible electrical shock.
4. How to Hang Your Ceiling Fan
(Continued)
1/2-INCH
6 TO 9
INCHES
Figure 9
AT LEAST
7'
Figure 10
8
BLACK WIRE
WHITE WIRE
HANGER BALL
CEILING
FLOOR