Problem
Little or no water delivered
Bleeder orifice check valve
stuck or installed back-wards
(standard tank only).
Low water level.
Low voltage.
Plugged intake screen.
Check valve at pump dis-
charge stuck.
Worn impellers and dif-
fusers.
Air or milky water discharge from faucets
Gas in well water.
Air volume control not work-
ing (standard tanks only).
For parts or assistance, call Simer Customer Service at 1-800-468-7867 / 1-800-546-7867
All manuals and user guides at all-guides.com
TROuBLESHOOTING GuIdE (cont.)
Check
Examine valve.
Determine lowest water level in well
while pump is running and compare
to pump depth setting.
Check voltage at control box with
pump running. Check incoming wire
size and power supply wire size
against Table III, Page 4.
Pull pump and check condition of
screen.
Pull pump and examine check valve.
Make sure system is clear of obstruc-
tions and pump is in solid water and
operation normally.
Check for presence of gas in well
water.
Make sure ports and ball check
valves are clear.
11
Corrective Action
If stuck, free valve; if installed backwards,
reverse it.
Lower pump further into well (but at least 5'
(1.6M) above bottom of well). Throttle pump
discharge until discharge equals recovery
rate of well. NOTICE: Running pump while
airlocked can cause loss of prime and seri-
ously damage pump.
Install larger wire from meter to control box.
Install larger wire from control box to pump.
If necessary, have power company raise sup-
ply voltage.
Clean or replace as necessary.
Free check valve.
Replace pump.
Remove bleeder orifices; plug tees. Be
sure plugged tees do not leak. If necessary,
separate
Replace control if necessary.