5 . S T O R A G E
5.1 Warning indicator
The UPS system contains no user-serviceable parts. If the battery service life (3~5 years at 25°C ambient temperature)
has been exceeded, the batteries must be replaced. In this case, please contact your dealer.
5.2 Storage
Before storing, charge the UPS 5 hours. Store the UPS covered and upright in a cool, dry location. During storage, recharge
the battery in accordance with the following table:
Storage Temperature
6 . S P E C I F I C A T I O N S
GENERAL CHARACTERISTICS
Technology
VA Capacity
Standard model
W capacity
Long Backup time model
Standard model
Power Factor
Long Backup time model
PHYSICAL CHARACTERISTICS
Dimensions D x W x H (mm) - UPS
Dimensions D x W x H (mm) - Battery bank
Standard Model
Dimensions D x W x H (mm) - Iso Bank
Net Weight (kg) - UPS + Battery bank
Net Weight (kg) - Iso Bank
Dimensions D x W x H (mm) - UPS
Long Backup time Model
Net Weight (kg)
INPUT
Low Line Transfer
(based on load percentage 100%-80%/ 80%-70%/ 70%-
Low Voltage Range
60%/ 60%-0%)
Low line Comeback
High Line Transfer
High Voltage Range
High Line Comeback
Frequency Range
Phase
Power Factor
OUTPUT (ISOLATION TRANSFORMER)
Voltage
AC Voltage Regulation (Batt, mode)
Frequency Range (Synchronized Range)
Frequency Range (Batt. Mode)
Allowable Overload : online mode
Current Crest ratio
Harmonic distorsion
Line mode to Battery mode
Transfer Time
Inverter to Bypass
Waveform
Output connection
EFFICIENCY
AC Mode
Eco mode
26
All manuals and user guides at all-guides.com
Recharge Frequency
-25°C - 40°C
40°C - 45°C
E6 LCD RT EVOLUTION
670 x 440 x 133 (3U)
635 x 440 x 133 (3U)
670 x 440 x 133 (3U)
670 x 440 x 133 (3U)
230 V
230 V
230 V
230 V
100-110% transfer to bypass after 10 min / 110-130% transfer to bypass after 1 min />130% transfer to bypass
INFOSEC UPS SYSTEM - 4, rue de la Rigotière - 44700 Orvault - FRANCE - www.infosec-ups.com
Hot Line – Tel + 33 (0)2 40 76 15 82 - Fax + 33 (0)2 40 94 29 51 - hotline@infosec.fr – 05 13 AA 59 206 14
Charging Duration
Every 3 months
Every 2 months
E6 LCD RT EVOLUTION
E6 LCD RT EVOLUTION
TX 5000 (S)
TX 6000 (S)
On line Double Conversion
5000 VA
6000 VA
4500 W
5400 W
4500 W
5400 W
0,9
670 x 440 x 133 (3U)
635 x 440 x 133 (3U)
670 x 440 x 133 (3U)
20 + 59
20 + 59
67
67
670 x 440 x 133 (3U)
20
20
176 VAC to 110 VAC +/-2%
186 VAC to 120 VAC +/-2%
300 VAC
290 VAC
50 Hz : 46 Hz ~ 54 Hz ou 60 Hz : 56 Hz ~ 64 Hz
Single phase with ground
0,99 at 100% load
100 / 104 / 110 / 115 / 120 / 208 / 220 / 230 / 240 VAC
+/- 1%
50 Hz : 46 Hz ~ 54 Hz ou 60 Hz : 56 Hz ~ 64 Hz
50 Hz +/- 0,1 Hz ou 60 Hz +/- 0,1 Hz
after 1 sec
3 : 1 (max)
<= 2% THD (linear load); <= 4% THD (batt mode before shut down)
Zero
Zero
Pure sinewave
Terminal board
90%
96%
1-2 hours
1-2 hours
E6 LCD RT EVOLUTION
TX 8000 (S)
TX 10000 (S)
8000 VA
10000 VA
7200 W
9000 W
7200 W
9000 W
745 x 440 x 133 (3U)
745 x 440 x 133 (3U)
635 x 440 x 133 (3U)
635 x 440 x 133 (3U)
745 x 440 x 133 (3U)
745 x 440 x 133 (3U)
23,5 + 65
23,5 + 65
90
90
745 x 440 x 133 (3U)
745 x 440 x 133 (3U)
23,5
23,5