Customer Settings; Recommended Settings - Stalgast 801350 Instrucciones De Uso

Ocultar thumbs Ver también para 801350:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 51
a. programming of temperatures and times

CUSTOMER SETTINGS

Press
. again. The displays will show the following data:
95
C)
o
The
arrows can be used to adjust the temperature on display 2.
Press
again. The displays will show the following data:
The
arrows can be used to adjust the temperature on display 2.
SERVICE SETTINGS (it is recommended that they are not changed)
Press
again. The displays will show the following data:
90
C).
o
The
arrows can be used to adjust the temperature on display 2.
Press
again. The displays will show the following data:
activation of the pressure switch (0-40 sec.) determining the water level.
The
arrows can be used to adjust the time of water release on display 2.
Press
again. The displays will show the following data:
The
arrows can be used to adjust the sanitization time on display 2.
During the setting of the above parameters the display screen is blinking, and the values of the parameters can be changed
using the arrows.
Function Name
Function description
P1
sanitization (rinsing) temperature
P2
washing temperature
P3
minimal sanitization temperature
P4
time for water release after the activation of
the pressure switch
P5
sanitization (rinsing) time
b. programming of cycle duration
Press
Display 1 will indicate:

RECOMMENDED SETTINGS

- 34 -
- sanitization-rinsing temperature (70-
- washing water temperature (40-70
- minimal sanitization temperature (50-
- time for water release after the
- sanitization time (8-15 sec.).
Recommended value
90ºC
60ºC
82ºC
20 seconds (for pressure of 2 bar)
15 seconds
C).
o

Publicidad

Tabla de contenido
loading