1
1. FDV in fuel hose
2. Sealing mechanism in fuel connector
3. Identification
Do NOT use a primer bulb/hose assembly
that does not contain a Fuel Demand Valve
or a sealing mechanism as shown below:
otherwise overflow the fuel system or fuel
spillage may occur.
ENOM00045-0
3. Starting
1. Be sure to install the stop switch lock
to the stop switch.
1
1. Stop switch lock
All manuals and user guides at all-guides.com
2
3
ENOF00035-0
ENOF00036-0
1
ENOF00037-0
ENGINE OPERATION
MF, MFG, EF, EFG, EFT type
2. Place the shift lever in the Neutral posi-
tion.
Be sure that the shift is in Neutral when
starting the engine.
This model is provided with start in
gear protection.
R
ENOW00031-0
CAUTION
If the engine starts in gear, do not use it.
Contact an authorized dealer.
ENON00010-0
Note
Start-in-gear protection prevents engine
from starting at other than neutral shift. In-
gear starting of engine will move the boat
immediately, potentially leading to falling
down or causing passenger(s) to be thrown
overboard.
3. Set the throttle grip to "START" posi-
tion.
35
N
F