Inrush protection:
IP20 per IEC 529.
Shock protection:
100g, 6ms, half‑period, per IEC 68‑2‑27.
Drop height, all angles:
1 metre.
Vibration resistance:
10/55/10Hz, 0.15mm, per IEC 68‑2‑6.
Bumps:
40g, 6ms, 4,000 bumps, per IEC 68‑2‑29.
4.4. ELECTRIC SAFETY
Protection against electric shocks
Per IEC 61010‑2‑032, 600V, CAT III, pollution degree 2.
Electromagnetic compatibility
Emissions and immunity in an industrial setting compliant with IEC 61326‑1.
Nondestructive peak current limit as a function of frequency
Ip (Apeak)
140
100
50
0
100
10
1 000
10 000
22
f (Hz)