7
Arc length
Allows regulation of the arc length during welding.
Minimum -5.0, Maximum +5.0, Default syn
10
Pre-gas
Allows you to set and adjust the gas flow prior to striking
of the arc.
Permits filling of the torch with gas and preparation of
the environment for welding.
Minimum off, Maximum 25 sec., Default 0.1 sec.
11
Soft start
Permits adjustment of the wire feed speed in the phases
prior to arc striking.
Given as a % of the wire speed set.
Permits striking at reduced speed, therefore softer and
with less spatter.
Minimum 10%, Maximum 100%, Default 50%
12
Motor slope
Allows you to set a gradual transition between the
sparking wire speed and the welding wire speed.
Minimum off, Maximum 1.0 sec., Default off
15
Burn back
Permits adjustment of the wire burn time, preventing
sticking at the end of welding.
Permits adjustment of the length.
Permits adjustment of the length of the piece of wire
outside the torch.
Minimum -2.00, Maximum +2.00, Default syn
16
Post-gas
Permits setting and adjustment of the gas flow at the
end of welding.
Minimum off, Maximum 10 sec., Default 2 sec.
19
Duty cycle (double pulsed)
Permit adjustment of the duty cycle in double pulse.
Parameter setting: percentage (%).
Minimum 10%, Maximum 90%, Default 50%
20
Double pulsed
Allows enablement of the "Double Pulsed" function.
Allows regulation of the pulsation amplitude.
Parameter setting: percentage (%).
Minimum 0%, Maximum 100%, Default ±25%
Parameter setting: meters per minute (m/min).
Minimum 0.5m/min, Maximum 22m/min, Default
2.5m/min
21
Pulse frequency
Allows the impulse frequency to be regulated.
Minimum 0.1Hz, Maximum 5.0Hz, Default 2.0Hz
22
Secondary voltage
Allows regulation of the secondary pulsation level voltage.
Makes it possible to obtain greater arc stability during
the various pulsation phases.
Minimum -5.0, Maximum +5.0, Default syn
23
Pulsed slopes (double pulsed)
Allows setting of a slope time during the pulse operation.
Parameter setting: percentage (%).
Minimum 1%, Maximum 100%, Default 50%
All manuals and user guides at all-guides.com
24
Bilevel (4 Step - crater filler)
Permits adjustment of the secondary wire speed in the
bilevel welding mode.
If the welder now presses and releases the button quickly,
"
" can be used; by pressing and releasing it quickly
again, "
" is used again, and so on.
Parameter setting: Percentage (%).
Minimum 1%, Maximum 99%, Default off
25
Initial increment
Allows regulation of the wire speed value during the
first "crater-filler" welding phase.
Makes it possible to increase the energy supplied to
the part during the phase when the material (still cold)
requires more heat in order to melt evenly.
Minimum 20%, Maximum 200%, Default 120%
26
Crater filler
Allows regulation of the wire speed value during the weld
closing phase.
Makes it possible to reduce the energy supplied to the part
during the phase when the material is already very hot,
thus reducing the risk of unwanted deformations.
Minimum 20%, Maximum 200%, Default 80%
27
Initial increment time
Lets you set the initial increment time. Lets you auto-
mate the "crater filler" function.
Minimum 0.1s, Maximum 99.9s, Default Off
28
Crater filler time
Lets you set the "crater filler" time. Lets you automate
the "crater filler" function.
Minimum 0.1s, Maximum 99.9s, Default Off
30
Spot welding
Allows you to enable the "spot welding" process and
establish the welding time.
Minimum 0.1s, Maximum 25s, Default off
31
Pause point
Allows you to enable the "pause point" process and
establish the pause time between one welding opera-
tion and another.
Minimum 0.1s, Maximum 25s, Default off
34
Initial increase slope
Allows to set a gradual transition between the initial
wire speed and the welding wire speed.
Parameter setting: seconds (sec.).
Minimum 0 sec., Maximum 10 sec., Default Off
35
Crater filler slope
Allows to set a gradual transition between the welding
wire speed and crater filler wire speed.
Parameter setting: seconds (sec.).
Minimum 0 sec., Maximum 10 sec., Default Off
202
Inductance
Allows electronic regulation of the series inductance of
the welding circuit.
Makes it possible to obtain a quicker or slower arc to
compensate for the welder's movements and for the
natural welding instability.
Low inductance = reactive arc (more spatter).
High inductance = less reactive arc (less spatter).
Minimum -30, Maximum +30, Default syn
330
Voltage
Lets you set welding voltage.
399
Welding speed
Lets you set welding speed.
Minimum 1cm/min, Maximum 500cm/min, Default
35cm/min (reference speed for manual welding)
47