Appliance Deactivation; Reset Intervention - Thermal Restore; Emergency Stop; Start-Up Subsequent To An Emergency Stop - Senco AC33024 Instrucciones De Empleo

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 57
DO NOT FULLY SCREW THE OULET PRESSURE
GAUGE (4) OR YOU RISK DAMAGING THE
MEMEBRANE.
4)
Connect the utensil to the air pipe (extension).
5)
Connect the air pipe (extension) to the air outlet spigot (5)
AIR PIPES (EXTENSIONS), CONNECTIONS AND
UTENSILS WHICH CONFORM TO DETAILS AS
SPECIFIED IN THE INSTRUCTION MANUALS
PROVIDED BY THE RELEVANT MANUFACTURERS
MUST BE USED.
IT IS STRICTLY FORBIDDEN TO USE UNSUITABLE AIR HOSES
(EXTENSIONS), FITTINGS AND TOOLS THAT DO NOT COMPLY
WITH CURRENT REGULATIONS.
6)
Carry out operations (the appliance will re-start automat-
ically in the instance where the operating pressure falls
below 7 bar).
7)
Upon termination of operations, switch off the appliance
as described in Paragraph 21.

21. APPLIANCE DEACTIVATION

At the end of operations, switch off the appliance as follows:
1)
Switch off the appliance using the "ON-OFF" switch (3)
ensuring it is set to "OFF (0)".
2)
Disconnect the appliance from the power supply (1) by
unplugging it.
3)
Disconnect the utensil from the air pipe (extension).
4)
Disconnect the air pipe (extension) from the appliance air
outlet spigot (5).
5)
Drain the tank condensate pump only once the work cycle
is terminated (A)..
22. RESET INTERVENTION – THERMAL RESTORE
In the instance where current overload and/or a short circuit
of the appliance electrical system is noted, the thermal restore
intervenes, disabling the electric motor. To carry out the reset
intervention, proceed as follows:
1)
Turn the "ON-OFF" switch (3) to the "OFF (0)" position.
2)
Press the thermal restore button (B).
3)
Wait a few moments before restarting the appliance.
MAINTENANCE PERSONS AND/OR THE AUTHORISED
SUPPLIER.

23. EMERGENCY STOP

Appliance emergency stop can be carried out by turning the
"ON-OFF" switch (3) to the "OFF (0)" position.
In order to avoid any possible danger, authorised operators
must carry out the following operations.
1)
IMMEDIATELY BRING THE "ON-OFF" SWITCH TO THE
"OFF (0)" POSITION (3).
2)
IMMEDIATELY NOTIFY THE "SAFETY MANAGER"
(WHERE THE APPLIANCE IS USED IN A BUSINESS CON-
TEXT) OF THE EMERGENCY.

24. START-UP SUBSEQUENT TO AN EMERGENCY STOP

After having resolved the issues which offset the emergency,
and checked that no damage and/or anomalies have been
caused to the appliance, with the consent of the safety manager
(where the appliance is used in a business context) start the
appliance as described in Paragraph 20.

25. STANDARD MAINTENANCE

All activities carried out to ensure use and operation of the ap-
pliance, via various intervention types (regulation, valve checks,
cleaning of air filters, etc.) executed by the authorised mainte-
nance person according to pre-established time intervals.
A
SAFETY MANAGER (WHERE THE APPLIANCE IS USED IN A
BUSINESS CONTEXT).
IT IS FORBIDDEN FOR AUTHORISED OPERATORS TO LEAVE
THE APPLIANCE UNSUPERVISED DURING OPERATION AND
MAINTENANCE INTERVENTIONS.
9
IF, AFTER CARRYING OUT THERMAL RESTORE, THE
APPLIANCE DOES NOT RESTART, THE QUALIFIED
OPERATOR MUST REQUEST THE INTERVENTION OF
Back view
AUTHORISED OPERATORS MUST ONLY CARRY OUT
OPERATIONS FOR WHICH THEY ARE QUALIFIED (SEE
PARAGRAPH 2) AND WITH THE CONSENT OF THE
EN