Eu Declaration Of Conformity; Technical Data - EUCHNER TZ Serie Manual De Instrucciones

Interruptores de seguridad
Ocultar thumbs Ver también para TZ Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Operating Instructions
Safety Switches TZ...

EU declaration of conformity

The declaration of conformity is part of the operating
instructions, and it is included as a separate sheet
with the device.
The original EU declaration of conformity can also
be found at: www.euchner.com
Service
If servicing is required, please contact:
EUCHNER GmbH + Co. KG
Kohlhammerstraße 16
70771 Leinfelden-Echterdingen
Service telephone:
+49 711 7597-500
E-mail:
support@euchner.de
Internet:
www.euchner.com

Technical data

Parameter
Value
Housing material
Anodized die-cast alloy
Degree of protection
Cable entry
IP67
Plug connector
IP65
Mechanical life
1 x 10
operating cycles
6
Ambient temperature
-25 ... +80 °C
Degree of contamination
3 (industrial)
(external, acc. to EN 60947-1)
Installation orientation
Any
Approach speed, max.
20 m/min
Extraction force (not locked)
30 N
Retention force
10 N
Actuating force, max.
35 N
Actuation frequency
1,200/h
Switching principle
Slow-action switching contact
Contact material
Silver alloy, gold flashed
Connection
TZ...
Cable entry M20 x 1.5
TZ...SR6
Plug connector SR6, 6-pin+PE
TZ...SR11
Plug connector SR11, 11-pin+PE
TZ...RC18
Plug connector RC18, 18-pin+PE
Conductor cross-section
0.34 ... 1.5 mm²
(flexible/rigid)
Rated insulation voltage
TZ...M, TZ...SR6
U
= 250 V
i
TZ...SR11
U
= 50 V
i
TZ...RC18
U
= 110 V
i
Rated impulse withstand voltage
TZ...M, TZ...SR6
U
= 2.5 kV
imp
TZ...SR11, TZ...RC18
U
= 1.5 kV
imp
Conditional short-circuit
100 A
current
Switching voltage, min.,
12 V
at 10 mA
Utilization category acc. to EN 60947-5-1
TZ...M, TZ...SR6
AC-15 4 A 230 V /
DC-13 4 A 24 V
TZ...SR11
AC-15 4 A 50 V /
DC-13 4 A 24 V
TZ...RC18
AC-15 4 A 110 V /
DC-13 4 A 24 V
Switching current, min.,
1 mA
at 24 V
Short circuit protection
(control circuit fuse)
4 A gG
acc. to IEC 60269-1
Convent. thermal current I
4 A
th
Solenoid operating voltage/solenoid power consumption
TZ...024
AC/DC 24 V (+10%/-15%) 10 W
TZ...110
AC
110 V (+10%/-15%) 10 W
TZ...230
AC
230 V (+10%/-15%) 10 W
Duty cycle
100 %
Locking force F
F
= 2000 N
max
S
F
Locking force F
max
Zh
(F
=
) = 1500 N
Zh
acc. to EN ISO 14119
1.3
Limitations at ambient temperature above +70 ... +80 °C
Utilization category acc. to EN 60947-5-1
TZ...SR6
AC-15 2 A 230 V /
DC-13 2 A 24 V
TZ...SR11
AC-15 2 A 50 V /
DC-13 2 A 24 V
Convent. thermal current I
2 A
th
Short circuit protection
2 A gG
according to IEC 60269-1
Reliability values acc. to EN ISO 13849-1
B
10D
3 x 10
6
at DC-13 100 mA/24 V
8
Illustration: guard closed, actuator locked
TZ..SR6
TZ..SR11
SK
SK
21
22
6
21
22
8
6
13
14
2
9
13
14
3
UK
UK
21
22
3
10
21
22
1
1
13
14
11
13
14
7
1
2
1
2
LED GN
LED GN
5
6
5
6
5
LED RD
LED RD
3
4
3
4
4
5
4
2
PE
PE
TZ..RC18...C1826
SK
1
41
42
2
11
33
34
5
3
21
22
4
11
12
UK
7
41
42
8
13
33
34
14
9
21
22
10
17
13
14
18
1
2
15
LED GN
5
6
16
LED RD
4
3
6
19
PE/12
TZ..SR6
TZ..SR11
5
4
3
6
3
2
2
1
1
TZ..RC18
12
11
1
18
10
2
17
13
19
9
3
16
14
8
4
15
7
5
6
View of connection side on the safety switch
Fig. 3: Connector assignments
TZ..RC18
SK
1
41
42
2
11
33
34
19
3
21
22
6
11
12
UK
7
41
42
8
13
33
34
14
9
21
22
10
17
13
14
18
1
2
15
LED GN
5
6
16
LED RD
4
3
4
5
PE/12
4
5
10
6
7
9
11
8

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Tz sr6 serieTz sr11 serieTz rc18 serieTz rc18 c1826 serie

Tabla de contenido