Idiomas disponibles

Operating Instructions
Safety Switches TP...
Notes about
The following information applies to devices
with cable entry:
For use and applications as per the requirements
of
, a copper wire for the temperature range
60/75 °C is to be used.
The following information applies to devices
with plug connector:
For use and applications as per the requirements of
, a class 2 power supply according to UL1310
must be used. Connection cables for safety switches
installed at the place of use must be separated
from all moving and permanently installed cables
and un-insulated active elements of other parts
of the system which operate at a voltage of over
150 V. A constant clearance of 50.8 mm must be
maintained. This does not apply if the moving cables
are equipped with suitable insulation materials which
possess an identical or higher dielectric strength
compared to the other relevant parts of the system.

EC declaration of conformity

The manufacturer named below herewith declares
that the product fulfills the provisions of the direc-
tive(s) listed below and that the related standards
have been applied.
EUCHNER GmbH + Co. KG
Kohlhammerstr. 16
D-70771 Leinfelden-Echterdingen
Directives applied:
Machinery directive 2006/42/EC
f
Standards applied:
EN 60947-5-1:2004 + Cor.:2005 + A1:2009
f
EN 1088:1995+A2:2008
f
EN 14119:2013
f
The original EC declaration of conformity can also
be found at: www.euchner.de
Service
If service support is required, please contact:
EUCHNER GmbH + Co. KG
Kohlhammerstraße 16
D-70771 Leinfelden-Echterdingen
Service telephone:
+49 711 7597-500
Fax:
+49 711 753316
E-mail:
support@euchner.de
Internet:
www.euchner.de

Technical data

Parameter
Value
Housing material
Reinforced thermoplastic
Degree of protection
acc. to IEC 60529
Cable entry
IP67
Plug connector SR6/SR11
IP65
Mechanical life
1 x 10
operating cycles
6
Ambient temperature
-20 ... +55 °C
Degree of contamination
3 (industrial)
(external, acc. to EN 60947-1)
Installation position
Any
Approach speed, max.
20 m/min
Extraction force (not locked)
20 N
Retention force
10 N
Actuating force, max.
10 N
Actuation frequency
1,200/h
Switching principle
Slow-action switching contact
Contact material
Silver alloy, gold flashed
Connection
TP...
Cable entry
TP...SR6
Plug connector SR6, 6-pin+PE
(PE not connected)
TP...SR11
Plug connector SR11, 11-pin+PE
(PE not connected)
Conductor cross-section
0.34 ... 1.5 mm²
(flexible/rigid)
Operating voltage for optional
L024 24 V
LED indicator
Rated insulation voltage
TP..., TP...SR6
U
= 250 V
i
TP...SR11
U
= 50 V
i
Rated impulse withstand voltage
TP..., TP...SR6
U
= 2.5 kV
imp
TP...SR11
U
= 1.5 kV
imp
Conditional short-circuit
100 A
current
Switching voltage, min.,
12 V
at 10 mA
Utilization category acc. to EN 60947-5-1
TP..., TP...SR6
AC-15 4 A 230 V /
DC-13 4 A 24 V
TP...SR11
AC-15 4 A 50 V /
DC-13 4 A 24 V
Switching current, min.,
1 mA
at 24 V
Short circuit protection
(control circuit fuse)
4 A gG
acc. to IEC 60269-1
Conv. thermal current I
4 A
th
Solenoid operating voltage/solenoid power consumption
TP...024
AC/DC 24 V (+10%/-15%) 8 W
TP...048
AC/DC 48 V (+10%/-15%) 8 W
TP...110
AC
110 V (+10%/-15%) 10 W
TP...230
AC
230 V (+10%/-15%) 11 W
Duty cycle
100%
Locking force F
max
TP1/TP2/TP3/TP4
F
= 1,300 N
S
TP5/TP6
F
= 800 N
S
F
Locking force F
max
Zh
(F
=
) = 1,000 N
Zh
acc. to EN ISO 14119
1.3
Reliability values acc. to EN ISO 13849-1
B
3 x 10
6
10d
8