9. Mounting the pump in the tank
DANGER
Electric shock
Death or serious personal injury
- The protective earth of the socket outlet
must be connected to the protective
earth of the pump. Therefore the
applied plug must have the same PE
connection system as the socket outlet,
or a suitable adapter must be applied.
1. Fit the retainer and the lever arm to the
pump. The choice of fitting hole in the
retainer for AP pumps depends on the
desired start/stop level. For AP pumps,
we recommend that you use the lowest
mounting hole, see drawing.
2. Secure the level switch of the pump to
the lever arm.
3. Fit the non-return valve in the pump
outlet port. Important: The valve flap
must be uppermost.
10
Unilift AP12
Unilift KP 150 / KP 250