Post-Operation & Clean-Up Instructions; To Stop The Cleaning Operation; Post-Operation Checklist; To Drain The Solution Tank - Nilfisk-Advance 7765 Serie Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

POST-OPERATION & CLEAN-UP INSTRUCTIONS

TO STOP THE CLEANING OPERATION

Discontinue the cleaning operation whenever a solution or recovery warning or stop light is illuminated.
The solution light will illuminate when the solution tank is empty. At this time, discontinue the scrubbing cycle, put all controls in position for transport
and drive to the drain area. See instructions on how to drain and clean the recovery and solution tanks, and empty the debris hopper.
The recovery warning light will illuminate approximately 5 minutes before loss of vacuum to the recovery tank. This warning period should give
ample time to complete the scrubbing cycle and transport or scrub to the drain area.

POST-OPERATION CHECKLIST

1.
Clean debris hopper.
2.
Check sweeping broom for wear or damage.
3.
Check all fl aps for wear, damage and adjustment.
4.
Drain and clean solution tank (ESP system)
5.
Clean solution fi lter screen (ESP system)
6.
Drain and clean recovery tank.
7.
Clean recovery tank screens and fl oats.
TO DRAIN SOLUTION TANK (RECYCLING OPERATION) (ESP SYSTEM)
Draining the solution tank is accomplished by a 4-foot (92 cm.) long drain hose located under the frame channel. To drain the tank, lower the hose,
remove the plug and drain. When the draining operation is completed, clean the solution tank as outlined below.
TO CLEAN SOLUTION TANK (RECYCLING OPERATION) (ESP SYSTEM)
Cleaning the solution tank is simplifi ed by the large access cover. Flush all deposits from the tank, also fl ush all probes and the solution line strainer
to remove any deposits - remove strainer if necessary. When the cleaning operation is completed, plug and replace the hose. Close and secure
covers.
TO DRAIN RECOVERY TANK
A 4-foot long drain hose for the recovery tank is located under the frame channel. To drain the tank, lower the hose, remove the plug and drain.
Open the recovery tank and remove the drain plug. When the draining operation is completed, fl ush and clean the recovery tank as outlined on the
next page.
After stopping the engine, perform this post-operation checklist.
8.
9.
10. Check rear and side squeegees for wear, damage and adjustment.
11. Fill fuel tank.
12. Check all systems for leaks.
FIGURE 19
NOTE
Check manifold and vacuum hoses for debris or obstructions,
backfl ush if necessary.
Check scrub brushes for wear or damage.
ENGLISH / A-23