The engine is equipped with a low-oil-shutoff and
this will stop when the oil level in the crankcase falls
below the threshold level.
?
NOTE
Check oil often during the break-in period. Refer to
the Maintenance section for recommended service
intervals.
?
NOTE
The generator rotor has a sealed, pre-lubricated
ball bearing that requires no additional lubrication
for the life of the bearing.
1. LPG gas pressure area:0.2~0.7MPa.
2. DO NOT use gasoline as fuel.
3. Connect LPG tube on LPG tank and fasten it.
4. Turn the LGP tank valve to "ON" position - full
open.
5. Screw on the trachea tie-in
6. Check all connections for propane leaks with
soapy water and tighten connections.
7. If air pressure is low change the tank. When
propane pressure is low, replace with a full
tank.
Tel: (888)696-2345
Use clean, fresh, regular LPG with LPG gas
pressure area:0.2~0.7MPa.
DO NOT mix oil with fuel.
DO NOT use gasoline as fuel.
Connect LPG tube on LPG tank and fasten it.
Turn the LGP tank valve to "ON" position - full open.
Screw on the trachea tie-in
Check the LPG to see if it is leaking and then
guarantee it.
When the air-pressure is lower than standard range,
please change LPG tank.
Grounding
Your generator must be properly connected to an
appropriate ground to help prevent electric shock.
Failure to properly ground the generator can result
in electric shock.
A ground terminal connected to the frame of the
generator has been provided on the power panel.
For remote grounding, connect a length of heavy
gauge (14 AWG minimum) copper wire between the
generator ground terminal and a copper rod driven
into the ground. We strongly recommend that you
consult with a qualified electrician to ensure
compliance with local electrical codes.