Generator will not start
Generator will not start;
Generator starts but runs roughly
Generator shuts down during
operation
Generator cannot supply enough
power or overheating
No AC output
Generator gallops
Repeated circuit breaker tripping
Eastern Tools & Equipment, Inc. will repair or replace, free of charge, any part or parts of the generator that are
defective in material or workmanship or both. Transportation charges on parts submitted for repair or replacement under
this Warranty must be borne by purchaser. This warranty is effective for the time period and subject to the conditions
provided for in this policy. For warranty service, find the nearest Authorized Service Dealer by contacting the place of
Tel: (888)696-2345
No Propane
Faulty spark plug
Unit loaded during start up
Low oil level
Choke in the wrong position.
Spark plug wire loose
Out of Propane
Low oil level
Generator is overloaded
Insufficient ventilation
Cable not properly connected
Connected device is defective
Circuit breaker is open
Capacitor defective
Faulty brush assembly
Faulty AVR
Loose wiring
Other
Engine governor defective
Overload
Faulty cords or device
LIMITED WARRANTY
Web Site: easterntools.com
New Tank
Replace spark plug
Remove load from unit
Fill crankcase to the proper level
Place generator on a flat, level surface
Adjust choke.
Attach wire to spark plug
Refill propane
Fill crankcase to the proper level.
Place generator on a flat, level surface
Review load and adjust. See "Power
Management"
Check for air restriction. Move to a well
ventilated area
Check all connections
Replace defective device
Reset circuit breaker
Replace capacitor (Service Center)
Replace brush assembly (Service Center)
Replace AVR (Service Center)
Inspect and tighten wiring connections
Contact the help line.
Contact the help line
Review load and adjust. See "Power
Management"
Check for damaged, bare or frayed wires.
Replace defective device