BUILT-IN INSTALLATION SPECIFICATIONS
OVERALL DIMENSIONS
All Refrigerator / All Freezer Models
Model ICBBI-36R
All Refrigerator
W
H
D
914 mm
2138 mm
610 mm
Model ICBBI-36RG
All Refrigerator with Glass Door
W
H
D
914 mm
2138 mm
610 mm
Model ICBBI-36F
All Freezer
W
H
D
914 mm
2138 mm
610 mm
Unit dimensions may vary by ± 3 mm.
914 mm
Model ICBBI-36R
DOOR CLEARANCE
All Refrigerator / All Freezer Models
A
Model ICBBI-36R
946 mm
959 mm Flush Inset
Model ICBBI-36RG
946 mm
959 mm Flush Inset
Model ICBBI-36F
946 mm
959 mm Flush Inset
Door clearance is based on stainless
steel door and handle dimensions.
606 mm
BEHIND
FRAME
A
WIDTH
OF UNIT
4
All manuals and user guides at all-guides.com
2134
2134
mm
mm
914 mm
610 mm
Model ICBBI-36RG
2134
mm
914 mm
610 mm
Model ICBBI-36F
Stainless steel design shown.
INSTALLATION SPECIFICATIONS
*ANTI-TIP BRACKET MUST NOT
All Refrigerator / All Freezer Models—
INTERFERE WITH WATER LINE.
REFER TO INSTALLATION
Overlay (non-flush inset) and Stainless Steel
INSTRUCTIONS FOR COMPLETE
DETAILS.
EXTEND WATER LINE APPROX
A
914 mm FROM BACK WALL.
Model ICBBI-36R
902 mm
Model ICBBI-36RG
902 mm
Model ICBBI-36F
902 mm
Dimensions are for finished rough openings.
Models ICBBI-36R and ICBBI-36RG will not
require the water line connection.
INSTALLATION SPECIFICATIONS
*ANTI-TIP BRACKET MUST NOT
All Refrigerator / All Freezer Models—
INTERFERE WITH WATER LINE.
REFER TO INSTALLATION
Flush Inset Application
INSTRUCTIONS FOR COMPLETE
DETAILS.
**ASSUMES 19 mm PANEL
A
B
THICKNESS.
EXTEND WATER LINE APPROX
Model ICBBI-36R
902 mm
965 mm
914 mm FROM BACK WALL.
Model ICBBI-36RG
902 mm
965 mm
Model ICBBI-36F
902 mm
965 mm
Dimensions are for finished rough openings.
Models ICBBI-36R and ICBBI-36RG will not
require the water line connection.
457 mm *
TOP VIEW
13 mm
610 mm
OPENING
OUTLINE OF
DEPTH
OVERLAY
OR STAINLESS
STEEL MODEL
LOCATE
610 mm
ELECTRICAL
OPENING
WITHIN
SHADED AREA
DEPTH
A
OPENING WIDTH
2127 mm
OPENING
HEIGHT
LOCATE WATER SUPPLY
WITHIN SHADED AREA
457 mm
W
76 mm
SIDE VIEW
FRONT VIEW
457 mm *
TOP VIEW
13 mm
610 mm
OPENING
OUTLINE
DEPTH
OF FLUSH INSET
APPLICATION WITH
19 mm PANEL
6 mm
56 mm **
610 mm
LOCATE
OPENING
ELECTRICAL
DEPTH
WITHIN
56
SHADED AREA
mm **
FLUSH INSET
665 mm
DETAIL
FLUSH INSET
DEPTH
6
mm
56
mm
610 mm
OPENING
2134
2127 mm
DEPTH
mm
OPENING
32
FLUSH
HEIGHT
mm
INSET
HEIGHT
A
32
OPENING WIDTH
B
mm
FLUSH INSET WIDTH
LOCATE WATER SUPPLY
WITHIN SHADED AREA
457 mm
W
76 mm
SIDE VIEW
FRONT VIEW
152
mm
WATER LINE
SHUT-OFF
VALVE
E
178
mm
152
mm
1918 mm
152
mm
152
mm
WATER LINE
665 mm
FLUSH INSET
DEPTH
SHUT-OFF
VALVE
E
178
mm
152
mm
1918 mm
32
mm
152
mm