IVT GN-750B Manual Del Usuario página 20

Generador a gasolina
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 186
Instruction manual
STORAGE TIME
Less than one month
1 to 2 monts
EN
2 months to 1 year
1 year or more
*Use gasoline conditioners that are formulated to extend storage life. Contact your authorized IVT generator
dealer for conditioner recommendations.
Always keep the tool and the ventilation slots (if
present) cleaned. Regular cleaning and maintenance of
the appliance will ensure efficiency and prolong the life
of your tool.
If the tool should fail despite the rigorous
manufacturing and testing procedures, the repair should
be carried out by an authorized IVT customer service.
Keep all nuts, bolts, and screws tight, to be sure the
tool is in safe working condition.
Replace worn or damaged parts for safety.
Use only original spare parts. Parts not produced
by manufacturer may cause poor fit and possible injury.
Store the tool in a dry room out of reach of kids and
away from any flammable material.
Store all fuel tanks securely. Never store the
equipment with fuel in the tank inside a building, where
fumes can reach an open flame or sparks.
Periodic maintenance and adjustment is necessary to
keep the generator in good operating condition. Perform
the service and inspection at the intervals shown in the
maintenance schedule.
WARNING! Exhaust gas contains
poisonous carbon monoxide. Shut
off the engine before performing
any maintenance. If the engine must
be run, make sure the area is well
ventilated.
NOTICE: use only genuine IVT parts or their
equivalent for maintenance or repair. Replacement
parts which are not of equivalent quality may
damage the generator.
All manuals and user guides at all-guides.com
RECOMMENDED SERVICE PROCEDURE TO PREVENT HARD STARTING
No preparation required.
Fill with fresh fuel and add gasoline conditioner*.
Fill with fresh fuel and add gasoline conditioner*.
Drain the carburetor float bowl.
Drain the fuel sediment cup.
Fill with fresh fuel and add gasoline conditioner*.
Drain the carburetor float bowl.
Drain the fuel sediment cup.
Remove the spark plug. Put a tablespoon of engine oil into the cylinder. Turn the engine slowly with the
pull rope to distribute the oil. Reinstall the spark plug.
(GN-2200B; GN-2700B; GN-3300B; GN-5500B; GN-6500B) Change the engine oil.
After removal from storage, drain the stored fuel into a suitable container, and fill with fresh fuel before
starting.
Engine oil change [F5]
(GN-2200B;
GN-2700B;
GN-6500B)
Drain the oil while the engine is warm to assure rapid
and complete draining.
1.
Remove the oil drain plug (8) and sealing washer,
oil filler cap (7) and drain the oil.
2.
Reinstall the oil drain plug (8) and sealing washer.
Tightern the plug securely.
3.
Refill with the recommended oil and check the
level.
CAUTION! Used motor oil may cause
skin cancer if repeatedly left in contact
with the skin for prolonged periods.
Although this is unlikely unless you
handle used oil on a daily basis, it
is still advisable to thoroughly wash
your hands with soap and water as
soon as possible after handing used
oil.
Please dispose of used motor oil in a manner that is
compatible with the environment. We suggest you take
it in a sealed container to your local service station or
recycling center for reclamation. Do not throw it in the
trash or pour it on the ground.
Air cleaner (12) service [F6]
A dirty air cleaner (12) will restrict air flow to the
carburetor. To prevent carburetor malfunction, service
the air cleaner regularly. Service more frequently when
operating the generator in extremely dusty areas.
20
GN-3300B;
GN-5500B;

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Gn-2200bGn-2700bGn-3300bGn-5500bGn-6500b

Tabla de contenido