NOTE:
For this application the use of PROMAX's RP-050 FI simulator is
suggested, for which it has been specially designed.
1.- CALIBRATION
Connect the RP-050 directly to the PROLINK-3/3C
adapter.
Power on the RP-050 through the PROLINK-3/3C Premium, it is necessary to set
the External supply function (see section '4.8 External Units Power Supply') pressing
key [27], and the rotary selector [4] for setting a voltage of 13 V.
Finally, select the SAT IF TEST application on FUNCTIONS menu from TV mode
and SAT band, when it appears the screen from figure 34, press the rotary selector [4]
to accede to the FUNCTIONS menu and using the rotary selector [4] to accede to the
Calibrate function (figure 35). Wait for some seconds until the calibration process is
completed shown by a white square crossing through the three pilot frequencies.
Figure 33.- Sat IF test selection, (satellite band, analogue channels).
Page 70
FUNCTIONS
LNB LOCAL OSC.
VIDEO POLARITY
SAT IF TEST
NEXT
PREVIOUS
10
FUNCIONES
0
-10
-20
- - MHz
- - MHz
REF.
- - dBuV
- - dBuV
TEST
- - dBuV
- - dBuV
ATT.
Figure 34.- Sat IF test.
USER'S MANUAL. PROLINK-3/3C
Premium
2/3
- - MHz
- - dBuV
- - dBuV
Premium
using the BNC-F
06/2005