4b. Well Seal Installation: After the pump
assembly is lowered into the well, mount
the well seal onto the well casing and
tighten the four bolts in the well seal evenly.
PRELIMINARY TEST RUN
WARNING: All electrical wiring or service
should be done by qualified electrician. Be sure
to test cable for continuity with an ohmmeter
before starting the pump.
1. All wells should be flushed clear before
allowing water into the house. (Fig. 1)
2. Open an outside faucet and allow water
to run until water is clear of sand or any
other impurities. If an outside faucet is not
available, place softener in bypass position,
remove aerator from a high-flow faucet
and allow water to run until it is clear of
impurities. Once clear, turn off water flow,
replace aerator and put softener back into
service position. (Fig. 2)
CAUTION: Be sure you do not stop pump
before water runs clear. This may take several
hours. If pump stops with sand in it, it may lock.
4b
1
Outside
Faucet
Fuse Box
2
Outside
Faucet
Pump in
Well
12
Pump in
Well