Dyna-Flo DGPH301BL Manual Del Propieratio página 20

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

CARE AND MAINTENANCE
Signs of possible blockage include:
Gas odor with extreme yellow tipping of flame.
Heater does NOT reach the desired temperature.
Heater glow is excessively uneven.
Heater makes popping noises.
Spiders and insects can nest in burner or orifices. This dangerous condition can damage heater and render
it unsafe for use. Clean burner holes by using a heavy-duty pipe cleaner. Compressed air may help clear
away smaller particles.
Carbon deposits may create a fire hazard. Clean dome and burner screen with warm soapy water if any
carbon deposits develop.
Battery check: Please ensure the battery is installed before use. Take out the battery if the unit will not be
used for a long time.
Note: In a salt-air environment (such as near an ocean), corrosion occurs more quickly than normal.
Frequently check for corroded areas and repair them promptly.
Storage
Between uses:
Turn off control valve and cylinder valve.
Disconnect the hose regulator from propane cylinder.
Remove the battery from the igniter.
Store heater upright in an area sheltered from direct contact with inclement weather (such as rain, sleet,
hail, snow, dust and debris).
If desired, cover heater to protect exterior surfaces and to help prevent build-up in air passages.
Note: Wait until heater is cool before covering.
During periods of extended inactivity or when transporting:
Turn off control valve and cylinder valve.
Disconnect the hose regulator and move the cylinder to a secure, well ventilated, outdoor location.
Remove the battery from the igniter.
Store heater upright in an area sheltered from direct contact with inclement weather (such as rain, sleet,
hail, snow, dust and debris).
If desired, cover heater to protect exterior surfaces and to help prevent build-up in air passages.
Never leave LP cylinder exposed to direct sunlight or excessive heat.
Note: wait until heater is cool before covering.
Service
Only a qualified service person should repair gas passages and associated components.
Caution: Always allow heater to cool before attempting service.