PROBLEM
Smell of gas
Flame flashback beneath
control panel
Gas leak detected from
cylinder, regulator, or other
connection
Grease fire or continuous
excessive flames above
cooking surface
Burners will not light
Decreasing heat or popping
sound
Hot spots on cooking
surface
Yellow flame
Inside of lid appears to be
peeling

TROUBLESHOOTING

CAUSE
Gas cylinder valve open.
Hose, regulator, or valve leaking.
Fire in burner tube due to blockage.
Improper installation and loose
connections.
Mechanical failure due to rusting or
mishandling.
Grease build up in burner area.
LP gas cylinder is empty.
Trying to light wrong burner.
Burner not connected to control knob.
Venturi blocked.
Vapor lock at coupling nut to LP
cylinder.
Ignitor wire(s) are loose, dirty, or not
connected.
Dead battery in ignitor.
LP gas cylinder is empty.
Venturi blocked.
Venturi blocked.
Venturi or burners may be blocked.
This is a build up of grease. The inside
of the lid is not painted.
Turn off cylinder valve immediately and tighten
connections.
Turn off cylinder valve immediately and check
for damaged hose, regulator, or valve. Perform
leak test, see Testing Valves, Hose, and
Regulator for Leaks in the Assembly section.
See Cleaning Burner Assembly and Checking
Venturi for Insects in the Maintenance section.
Tighten fittings and see Testing Valves, Hose,
and Regulator for Leaks in the Assembly section.
Replace or refill LP gas cylinder.
Turn off control knobs and cylinder valve. Leave
hood open allowing flames to extinguish. Once
cool, clean grill thoroughly.
Replace or refill LP gas cylinder.
See Igniting the Main Burner in the Operation
section.
Make sure valves are inside the burner tubes.
See Testing Valves, Hose, and Regulator for
Leaks in the Assembly section.
Turn off control knobs and cylinder valve.
Reconnect burner electrode wires or replace
the ignitor wire assembly. Clean wires and/
or electrode with rubbing alcohol and a clean
swab. Tighten all connections.
Replace the battery in the ignitor.
Replace or refill LP gas cylinder.
See Testing Valves, Hose, and Regulator for
Leaks in the Assembly section.
See Testing Valves, Hose, and Regulator for
Leaks in the Assembly section.
See Testing Valves, Hose, and Regulator for
Leaks in the Assembly section.
Clean with a soft bristle brush or scraper.