Regulating the minimum flow
Connecting to LPG
40
To regulate the minimum flow of valved cooking hob
taps, proceed as follows:
• Switch on the burner and turn the control knob
towards the low flame - position.
• Remove the control knob.
• Using a screwdriver, adjust the internal adjust-
ment screw (E) until the correct low flame is
E
obtained.
Unscrew the adjustment screw (E) to increase the
flow, or tighten it to reduce the flow.
The adjustment is correct when the low flame
measures approximately 3 or 4 mm.
• Refit the control knob.
• When changing quickly from the maximum to
minimum flow and vice versa make sure that the
flame does not go out.
If you want to connect the appliance to LPG, use a
pressure regulator and connect to the cylinder in
compliance with the guidelines set out in standards
regulations in force.