Gas connection
Gas connection on the
appliance
Safety valve
36
The appliance must be connected in accordance with
the local regulations currently in force.
Before the appliance is installed, check that the local
regulations (type of gas and gas pressure) and the
appliance settings are compatible. The appliance
setting requirements can be found on the
identification plate.
Connection to the gas lines and the seals must be
performed by a competent person in accordance with
current standards in force.
The 1/2" threaded connection for the gas line is on
the rear right of the appliance.
The gas connection installed on the appliance
complies with ISO 228-1. An adapter for connection
in accordance with ISO 7-1 is included with the
appliance.
On the following page, you will find a table of
countries with the respective connection required.
For butane or liquefied petroleum gas, a pressure
reducer conforming to standards must be provided.
Installation of a safety valve to open and shut off the
gas supply is mandatory.
Fit the safety valve between the gas supply pipe to
the appropriate room and the hob. Ensure that
access to this valve is unobstructed.