5-3-2. SPECIAL MENU
  SPECIAL MENU  V1.00
 PAGE      1/2
 CHROMA    L・・・・I・・・H
 DETAIL    L・・・・I・・・H
 PEDESTAL  L・・・・I・・・H
 VIDEO LEV.L・・・・I・・・H
 GAMMA     0.45
 MATRIX    A MODE
      RET   EXIT
(1) PAGE
(2) CHROMA
(3) DETAIL
(4) PEDESTAL
(5) VIDEO LEV. To be used to adjust the video level.
(6) GAMMA
(7) MATRIX
(8) MONITOR
(9) P.MASK
(10)MIRROR
(11) RS-485ID
(12)LANGUAGE To select language of menu screen (either English or French).
(13)RET/EXIT

5-4. Setup procedures

5-4-1. CAMERA ID
(1) CAMERA ID ON/OFF setting
Highlight CAMERA ID. Using the E, L
or R button, access the ON/OFF setting.
Decide the ON or OFF setting with the
L or R button.
PAGE (1/2, 2/2) can be selected with the "L" and "R" buttons.
To be used to adjust the Chroma level.
To be used to adjust the details.
Pedestal level control.
To be used to select the gamma correction.
Selection of MATRIX Mode.
Selection of Monitor types, CRT or LCD types.
Privacy Mask control.
To be used to select mirror-reversed images.
To be used to preset an ID number (1 to 207) for RS-485 link.
RET for returning to the main menu screen.
EXIT for saving parameters or to quit the procedure.
Highlight EXIT on the SETUP MENU
screen. Hold down the L and R buttons
together, and the screen at left appears
on screen.
      SETUP MENU
 CAMERA ID    OFF
 SENS UP      STD
 SHUTTER      X32 X32
 LIGHT CONT.  LENS
 GAIN         AGC
 WHITE BAL.   ATW1
 SYNC         INT
 MENU LOCK    OFF
 EXIT  CANCEL  RESET