Installation & Service Manual
WARTUNGS & INSTALLATIONS HANDBUCH
2
MANUAL DE SERVICIO & MANUAL DE INSTALACIÓN
5
MANUEL D'ENTRETIEN & MANUEL D'INSTALLATION
3
4
ONDERHOUDS & INSTALLATIEHANDLEIDING
1
:
INSTRUKCJA MONTAŻU I SERWISU
INSTALLATION & SERVICE MANUAL
2
18
34
50
66
82

Publicidad

loading

Resumen de contenidos para Zibro S1825

  • Página 1 S1825 - S1833 - S1847 Installation & Service Manual WARTUNGS & INSTALLATIONS HANDBUCH MANUAL DE SERVICIO & MANUAL DE INSTALACIÓN MANUEL D’ENTRETIEN & MANUEL D’INSTALLATION INSTALLATION & SERVICE MANUAL ONDERHOUDS & INSTALLATIEHANDLEIDING INSTRUKCJA MONTAŻU I SERWISU...
  • Página 2: Bestellung Von Ersatzteilen

    WICHTIGER HINWEIS Dieses Wartungshandbuch ist für die Verwendung durch Personen vorgesehen, die über ausreichend Hintergrundwissen im Bereich Elektrik, Elektronik, Kältetechnik und Maschinen verfügen. Jeder Versuch, das Gerät zu installieren oder zu reparieren, kann zu Personenschäden oder Beschädigungen des Geräts füh- ren.
  • Página 3 INHALT SICHERHEITSMASSNAHMEN INSTALLATION VON GERÄTEN FÜR DEN INNEN- UND AUSSENBEREICH ELEKTRISCHER ANSCHLUSS LUFTSPÜLUNG TESTBETRIEB WARNUNG! Installieren oder entfernen Sie das Gerät nicht selbst bzw. schließen Sie es nicht selbst erneut an. • Eine falsche Installation kann zu einem Wasseraustritt, Stromschlag, Kühlmittelaustritt oder zu einem Brand führen.
  • Página 4 SICHERHEITSMASSNAHMEN Folgende Punkte sollten aus Sicherheitsgründen immer eingehalten werden: • Lesen Sie die folgende WARNUNG vor der Installation der Klimaanlage. • Befolgen Sie die hier aufgeführten Vorsichtsmaßnahmen, da sie wichtige Punkte in Bezug auf Ihre Sicherheit enthalten. • Heben Sie diese Anweisungen nach dem Lesen zusammen mit dem Benutzerhandbuch an einem siche- ren Ort auf, um später darin Informationen nachschlagen zu können.
  • Página 5 VORSICHTSMASSNAHMEN Installieren Sie das Gerät nicht an Orten, an denen brennbare Gase entweichen. • Wenn Gas austritt und sich um das Gerät ansammelt, kann es zu einer Explosion kommen. Führen Sie die Entlüftungs- bzw. Rohrarbeiten gemäß den Installationsanweisungen durch. • Wenn die Entlüftungs- bzw. Rohrarbeiten falsch ausgeführt werden, kann Wasser aus dem Gerät austreten und Gegenstände im Haushalt nass machen und beschädigen.
  • Página 6 Gerät für den Außenbereich • Vergewissern Sie sich, dass die Wärmestrahlung des Verdampfers nicht behindert ist, wenn über dem Gerät für den Außenbereich eine Markise gebaut ist, um direkte Sonneneinstrahlung oder Regenwasser auf dem Gerät zu vermeiden. • Achten Sie darauf, dass hinter dem Gerät und links daneben ein Abstand von mindestens 30 cm vor- handen ist.
  • Página 7 Mindestens 15 cm. Luftauslass Fernsteuerung Blechschraube B ST 2,9 x 10-C-H Bilden Sie mit dem Halterung für Fernsteuerung Anschlusskabel eine Schleife. VORSICHT • Achten Sie darauf, dass links und rechts neben dem Gerät für den Innenbereich ein Abstand von mehr als 12 cm vorhanden ist. Das Gerät für den Innenbereich sollte mindestens 15 cm von der Decke entfernt angebracht werden.
  • Página 8 1. Anbringen der Installationsplatte Befestigen Sie die Installationsplatte horizontal an Konstruktionselementen der Wand und achten Sie darauf, dass um die Installationsplatte ein Abstand vorhanden ist. Bohren Sie bei Ziegelwänden, Betonwänden usw. acht Löcher mit einem Durchmesser von 5 mm in die Wand.
  • Página 9 2. Bohren Sie ein Loch in die Wand. Bestimmen Sie anhand der Zeichnung in Abbildung 5 die Lochpositionen und bohren Sie ein Loch 65 mm tief in die Wand, wobei das gebohrte Loch leicht zur Außenseite hin schräg verläuft. Dadurch wird verhindert, dass Wasser in den Innenbereich gelangt.
  • Página 10 Oberer Haken Unterer Haken Polstermaterial Abb. 9 4. Installation des Geräts für den Innenbereich Führen Sie die Rohre durch das Loch in der Wand. Bringen Sie die obere Klammer auf der Rückseite des Geräts für den Innenbereich auf dem oberen Haken der Installationsplatte an und bewegen Sie das Gerät seitwärts, um zu überprüfen, ob es sicher eingehängt ist.
  • Página 11 INSTALLATION DES GERÄTS FÜR DEN AUSSENBEREICH Sicherheitsmaßnahmen für die Installation des Geräts für den Außenbereich • Installieren Sie das Gerät für den Außenbereich auf einem starren Untergrund, um übermäßige Betriebsgeräusche und Vibrationen zu verhindern. • Bestimmen Sie den Bereich für die Luftauslassöffnungen, an dem die abgegebene Luft nicht blockiert wird.
  • Página 12: Elektrischer Anschluss

    festzudrehen. Verbinden Sie das Verbindungsstück für das Entleeren mit dem Ablaufschlauch (nicht im Lieferumfang enthalten). Damit kann Kondenswasser, das während des Heizmodus der Klimaanlage erzeugt wird, abgelassen werden. Verbindungss tück für das Dichtring Öffnung an der Unterseite des Entleeren Geräts für den Außenbereich Dichtring Ablaufrohr Abb.
  • Página 13 Die zugeführte Spannung sollte im Bereich von 95 bis ca. 105 % der Nennspannung in einer Tabelle mit der Nennspannung liegen. Im Stromkreis sollten ein Kriechstromschutz und ein Hauptschalter mit einer 1,5-fachen Leistung des Maximalstroms des Geräts installiert sein. Achten Sie darauf, dass die Klimaanlage gut geerdet ist. Schließen Sie die elektrischen Leitungen gemäß...
  • Página 14 Schließen Sie das Kabel am Gerät für den Außenbereich an (siehe Abb. 21) Entfernen Sie die elektrischen Bauteile vom Gerät für den Außenbereich. Schließen Sie die Verbindungskabel an die Anschlüsse auf dem Anschlussblock der Geräte für den Innen- und Außenbereich an, die über die entsprechenden Nummern verfügen. Bilden Sie eine Schlaufe der Verbindungskabel der Geräte für den Innen- und Außenbereich wie in der Zeichnung gezeigt, um das Eindringen von Wasser zu verhindern.
  • Página 15 • Feuchtigkeit im Kühlmittelkreislauf kann gefrieren und die Kapillarleitungen verstopfen. • Wasser kann zu Korrosion von Bauteilen im Kühlsystem führen. • Beschädigungen des Verdichters. Daher muss die Rohrverbindung zwischen dem Gerät für den Innen- und Außenbereich immer getestet und mithilfe einer Vakuumpumpe entleert werden, um nicht kondensierbare Gase und Feuchtigkeit aus dem System zu entfernen.
  • Página 16 Prüfpunkt bei Gerät für Innenbereich Abdeckung Prüfpunkt bei Gerät für Außenbereich Abb. 25 TESTBETRIEB Führen Sie einen Testbetrieb durch, nachdem Sie die Prüfung der elektrischen Streuung und die Gasleckprüfung abgeschlossen haben. Die Dauer des Testbetriebs sollte länger als 30 Minuten sein. Öffnen Sie die Abdeckung und heben Sie diese auf einen Winkel an, bis sie fest bleibt.
  • Página 18: Solicitud De Piezas De Repuesto

    AVISO IMPORTANTE: Este manual de servicio técnico está dirigido a personas con suficientes conocimientos de electricidad, elec- trónica, refrigeración y mecánica. Cualquier intento de instalar o reparar el aparato puede provocar lesio- nes y daños materiales. Ni el fabricante ni el vendedor se hacen responsables de la interpretación de esta información ni asumen ninguna responsabilidad en relación con su utilización.
  • Página 19 ÍNDICE PRECAUCIONES DE SEGURIDAD INSTALACIÓN DE LOS MÓDULOS INTERIOR Y EXTERIOR CONEXIONES ELÉCTRICAS PURGA DE AIRE PRUEBAS DE FUNCIONAMIENTO ¡AVISO! No instale, desinstale ni reinstale el aparato por sí mismo. • Una instalación incorrecta puede motivar fugas de agua, descargas eléctricas, pérdidas de refrigerante o incendios.
  • Página 20: Precauciones De Seguridad

    PRECAUCIONES DE SEGURIDAD Deberán observarse siempre las siguientes precauciones de seguridad: • Lea las siguientes ADVERTENCIAS antes de instalar el acondicionador de aire. • Siga las precauciones que se ofrecen aquí, ya que incluyen aspectos importantes relacionados con su seguridad. •...
  • Página 21: Instalación De Los Módulos Interior Y Exterior

    PRECAUCIONES No instale el aparato en un lugar donde existan escapes de gas inflamable. • Si existe un escape de gas y éste se acumula en la zona próxima al aparato, puede originarse una explosión. Instale los conductos y el desagüe de acuerdo con las instrucciones de instalación. •...
  • Página 22: Módulo Exterior

    Módulo exterior • Si se construye un toldo sobre el módulo exterior para protegerlo de la luz solar directa o de la lluvia, compruebe que no obstaculice la radiación térmica del condensador. • Asegúrese de que el espacio libre en la parte trasera del módulo y en el lateral izquierdo sea de 30 cm como mínimo.
  • Página 23: Instalación Del Módulo Interior

    15 cm o más Salida de aire Mando a distancia Tornillo de montaje B ST2,9 x 10-C-H Haga un bucle con el Soporte del mando a distancia cable de conexión PRECAUCIÓN • Asegúrese de que el aparato disponga de un espacio libre a ambos lados de más de 12 cm. El módulo interior debe instalarse a una distancia mínima de 15 cm del techo.
  • Página 24: Coloque La Placa De Instalación

    1. Coloque la placa de instalación Coloque la placa de instalación en horizontal sobre componentes que formen parte de la estructura de la pared con espacio suficiente alrededor. Si la pared es de ladrillo, hormigón o materiales similares, practique ocho orificios de 5 mm de diá- metro con un taladro.
  • Página 25: Practique Un Orificio En La Pared

    2. Practique un orificio en la pared Determine la posición del orificio de acuerdo con el diagrama indicado en la fig. 5. Practique un ori- ficio de 65 mm en dirección ligeramente descendente hacia el exterior, con el fin de evitar que el agua penetre en el interior.
  • Página 26: Conexiones Y Revestimiento

    Gancho superior Gancho inferior Almohadilla Fig. 9 4. Instalación del módulo interior Pase el conducto a través del orificio de la pared. Enganche la garra superior de la parte posterior del módulo interior en el gancho superior de la placa de instalación;...
  • Página 27: Instalación Del Módulo Exterior

    INSTALACIÓN DEL MÓDULO EXTERIOR Precauciones para la instalación del módulo exterior • Instale el módulo exterior sobre una base rígida para evitar incrementar el nivel de ruido y vibraciones. • Oriente la salida del aire hacia una dirección que esté libre de obstáculos. •...
  • Página 28: Conexión Del Conducto De Refrigerante

    Unión de desagüe Junta Orificio de la base del módulo exterior Junta Conducto de desagüe Fig. 13 CONEXIÓN DEL CONDUCTO DE REFRIGERANTE • Alinee el centro de los conductos. • Apriete lo suficiente la tuerca abocardada con los dedos y, después, apriétela con una llave de tuer- cas dinamométrica, como se indica (ver figs.
  • Página 29: Conexión Del Cable Al Módulo Interior

    Realice las conexiones de acuerdo con el esquema de conexión eléctrica adherido al panel del módulo exterior. Todas las conexiones deben cumplir con la normativa y los reglamentos locales y nacionales en materia eléctrica, y deben ser realizadas por un electricista cualificado. Debe utilizarse un circuito independiente y un enchufe exclusivo para el equipo de aire acondicionado.
  • Página 30: Purga De Aire

    Aísle los cables no utilizados (conductores) con cinta de PVC. Asegúrese de que no estén en contacto con ningún componente eléctrico ni metálico. One-twin Wiring Diagram Tapa Outdoor unit Outdoor power supply 220-240V-50HZ Tornillo Indoor unit Indoor power supply 220-240V-50HZ Indoor power supply Fig.
  • Página 31: Longitud Del Conducto Y Cantidad De Refrigerante

    LONGITUD DEL CONDUCTO Y CANTIDAD DE REFRIGERANTE Longitud del conducto de Cantidad de refrigerante adicional a la indicada Método de purga de aire conexión en la etiqueta que hay que cargar Utilice una bomba Menos de 5 m ------------------------ de vacío. Diámetro del conducto para líquido: Utilice una bomba De 5 a 10 m...
  • Página 32: Pruebas De Funcionamiento

    PRUEBAS DE FUNCIONAMIENTO Realice las pruebas de funcionamiento después de completar las comprobaciones de seguridad eléctrica y de fugas de gas. Las pruebas de funcionamiento deben durar más de 30 minutos. Abra el panel y levántelo hasta un ángulo en el que se mantenga fijo. No levante el panel más allá de que se detenga produciendo un chasquido.
  • Página 34: Commande De Pieces De Rechange : Proceduren

    NOTICE IMPORTANTE: Ce manuel d’entretien s’adresse à toute personne qui bénéficie de connaissances approfondies et d’une expérience solide en électricité, électronique, mécanique et techniques du froid. Tenter d’installer ou de réparer soi-même l’appareil est dangereux et peut entraîner des blessures ou endommager le matériel. Le fabricant ou le vendeur de cet équipement ne peut être tenu responsable de l’interprétation ou de l’utili- sation que fait l’utilisateur des informations contenues dans le présent manuel.
  • Página 35 TABLE DES MATIERES CONSIGNES DE SECURITE INSTALLATION DES UNITES INTERIEURE ET EXTERIEURE INSTALLATION ELECTRIQUE PURGE D’AIR TEST DE FONCTIONNEMENT AVERTISSEMENT! Ne pas installer, ôter et/ou réinstaller l’unité soi-même. • Une installation incorrecte de l’équipement peut entraîner des fuites d’eau ou de fluide frigorigène, des décharges électriques, voire provoquer un incendie.
  • Página 36: Consignes De Securite

    CONSIGNES DE SECURITE Les consignes de sécurité suivantes seront observées en toutes circonstances : • Lire attentivement l’AVERTISSEMENT ci-dessous avant d’installer le climatiseur. • Respecter les mises en garde énoncées dans ce manuel. Elles contiennent d’importantes informations de sécurité. • Après avoir lu ces instructions, veiller à...
  • Página 37: Unité Intérieure

    MISES EN GARDE Ne pas installer l’unité à proximité de fuites de gaz inflammables. • Le gaz qui s’échappe risque de s’accumuler autour de l’unité et de provoquer une explosion. Installer les éléments de drainage et de pompage conformément aux instructions d’installation. •...
  • Página 38: Unité Extérieure

    Unité extérieure • Si l’on protège l’unité extérieure des rayons solaires ou de la pluie à l’aide d’un auvent, s’assurer que la chaleur du condenseur peut s’échapper librement. • Prévoir un dégagement supérieur à 30 cm à l’arrière et du côté gauche de l’unité, à 200 cm à l’avant et à...
  • Página 39: Installation De L'UNite Interieure

    15 cm ou plus Sortie d’air Télécommande Vis de montage B ST 2,9 x 10-C-H Enrouler le câble de Support de télécommande connexion MISE EN GARDE • S’assurer que l’espace à gauche et à droite de l’unité intérieure est supérieur à 12cm. L’unité...
  • Página 40 1. Fixation du support de montage Fixer le support de montage horizontalement sur les structures du mur en prévoyant de l’espace tout autour. Si le mur est en briques, en béton ou en matériau similaire, percer huit trous de 5 mm de diamètre. Introduire le clip d’ancrage afin de garantir un montage correct des vis Fixer le support de montage...
  • Página 41: Tuyau De Raccordement

    2. Percer un trou dans le mur Déterminer la position des trous en fonction du diagramme illustré à la Fig.5. Percer un trou ( 65 mm) en inclinant légèrement vers le bas (côté extérieur) afin d’éviter la pénétration d’eau vers l’intérieur. Veiller à...
  • Página 42 Crochet supérieur Crochet inférieur Coussinet Fig. 9 4. Installation unité intérieure Faire passer le tuyau par l’ouverture pratiquée dans le mur. Placer l’attache supérieure située à l’arrière de l’unité intérieure sur le crochet supérieur du support de montage et déplacer l’unité latéralement pour s’assurer qu’elle est bien fixée. Pour raccorder les tuyaux, soulever l’unité...
  • Página 43: Installation De L'UNite Exterieure

    INSTALLATION DE L’UNITE EXTERIEURE Précautions d’installation de l’unité extérieure • Installer l’unité extérieure sur une base rigide afin d’éviter que le bruit et les vibrations ne soient ampli- fiés. • Déterminer le sens de l’évacuation de l’air de façon à ce que l’air soit évacué librement. •...
  • Página 44: Raccordement Du Tuyau Frigorifique

    le joint de drainage à l’extension du flexible de drainage (non livrée) afin que l’eau condensée qui se déga- ge lorsque le climatiseur fonctionne en mode chauffage puisse s’évacuer. Joint de drainage Ouverture dans le capot Garniture inférieur de l’unité exté- rieure Garniture Flexible de drainage...
  • Página 45: Important

    Une protection contre les fuites de courant et un interrupteur principal d’une capacité de 1,5 fois le cou- rant maximum de l’unité doivent être prévus dans le circuit électrique. S’assurer que le climatiseur est bien relié à la terre. Raccorder les câbles conformément au diagramme de connexions électriques situé sur le capot de l’u- nité...
  • Página 46 Afin d’éviter toute infiltration d’eau, faire une boucle dans le câble de raccordement comme illustré sur le diagramme d’installation des unités intérieure et extérieure. Isoler les cordons non utilisés (fils) à l’aide de ruban en PVC. Veiller à ce qu’ils ne touchent aucun élé- ment électrique ou métallique.
  • Página 47 LONGUEUR DE TUYAU ET QUANTITÉ DE FRIGORIGÈNE Quantité supplémentaire par rapport à la Longueur tuyau de Méthode de purge d’air quantité normale de frigorigène à charger raccordement (suivant l’ étiquette signalétique) Utiliser la pompe Moins de 5 m ------------------------ d’aspiration Utiliser la pompe Diamètre tuyau côté...
  • Página 48 Effectuer le test de fonctionnement après avoir achevé les contrôles de sécurité électrique et de fuite de gaz. Le test de fonctionnement doit durer plus de 30 minutes. Ouvrir le panneau et le soulever jusqu’à son point de fixation. Ne pas dépasser le niveau du déclic. Appuyer deux fois sur le bouton de commande manuelle jusqu’à...
  • Página 50: Important Notice

    IMPORTANT NOTICE: This service manual is intended for use by individuals possessing adequate backgrounds of electrical, elec- tronic, refrigerant and mechanical experience. Any attempt to install or repair the appliance may result in personal injury and property damage. The manufacturer or seller cannot be responsible for the interpreta- tion of this information, nor can it assume any liability in connection with its use.
  • Página 51 CONTENTS SAFETY PRECAUTIONS INSTALLATION OF INDOOR AND OUTDOOR UNITS ELECTRICAL WORK AIR PURGING TEST RUNNING WARNING! Do not install, remove and/or reinstall the unit by yourself. • Improper installation can cause water leakage, electrical shock, reffrigerant leakage or fire. Please consult authorized dealer or specialized air conditioner engineer for the installation work.
  • Página 52: Safety Precautions

    SAFETY PRECAUTIONS The following should be always observed for safety: • Be sure to read the following WARNING before installing the airconditioner. • Be sure to observe the cautions specified here as they include important items related to safety. • After reading this instructions, be sure to keep it together with the owners manual in a handy place for future reference.
  • Página 53: Installation Of Indoor And Outdoor Units

    CAUTIONS Do not install the unit in a place where a flammable gas leaks. • If gas leaks and accumulates in the area surrounding the unit, it could cause an explosion. Perform the drainage/piping work according to the installation instruction. •...
  • Página 54 • Ensure that the clearance around the back of the unit is more than 30cm and left side is more than 30cm. The front of the unit should have more than 200cm of clearance and the connection side (right side) should have more than 60cm of clearance. •...
  • Página 55: Indoor Unit Installation

    15 cm or more Air outlet Remote Controller Mounting screw B ST2.9x10-C-H Remote controller holder Loop the connective cable CAUTION • Ensure that the space around the left and right of the indoor unit is more than 12cm. The indoor unit should be installed allowing a minimum clearance of 15cm from the ceiling. •...
  • Página 56 1. Fit the Installation Plate Fit the installation plate horizontally on structural parts of the wall with spaces around the installa- tion plate. If the wall is made of brick, concrete or the like, drill eight (8) 5mm diameter holes in the wall. Insert Clip anchor for appropriate mounting screws Fit the installation plate...
  • Página 57: Drill A Hole In The Wall

    2. Drill a hole in the wall Determine hole positions according to the diagram detailed in Fig.5. drill one (1) hole ( 65mm) slanting slightly downwards to outdoor side, this will prevent water to come indoors. Always use wall hole conduit when drilling metal grid, metal plate or the like. 3.
  • Página 58 Upper Hook Lower Hook Cushion material Fig. 9 4. Indoor unit installation Pass the piping through the hole in the wall. Put the upper claw at the back of the indoor unit on the upper hook of the installation plate, move the indoor unit from side to side to see that it is securely hooked.
  • Página 59: Outdoor Unit Installation

    OUTDOOR UNIT INSTALLATION Outdoor installation precaution • Install the outdoor unit on a rigid base to prevent increasing noise level and vibration. • Determine the air outlet direction where the discharged air is not blocked. • In the case that the installation place is exposed to strong wind such as a seaside, make sure the fan operating properly by putting the unit lengthwise along the wall or using a dust or shield plates.
  • Página 60: Refrigerant Piping Connection

    Drain joint Seal Base pan hole of outdoor unit Seal Drain pipe Fig. 13 REFRIGERANT PIPING CONNECTION • Align the centre of the pipes. • Sufficiently tighten the flare nut with fingers, and then tighten it with a spanner and torque wrench as shown (see fig.
  • Página 61: Connect The Cable To The Indoor Unit

    All wiring must comply with local and national electrical standards and codes and be installed by qua- lified and skilled electricians. An individual branch circuit and single receptacle used only for this air conditioner must be available. See the following table for suggested wire sizes and fuse specifications: Input Rated Current Model Power supply...
  • Página 62: Air Purging

    One-twin Wiring Diagram Outdoor unit Cover Outdoor power supply 220-240V-50HZ Screw Indoor unit Indoor power supply 220-240V-50HZ Fig. 21 Indoor power supply 220-240V-50HZ CAUTION After the confirmation of the above conditions, prepare the wiring as follows: • Never fail to have an individual power circuit specifically for the air conditioner. As for the method of wiring, be guided by the circuit diagram posted on the inside of control cover.
  • Página 63 PIPE LENGTH AND REFRIGERANT AMOUNT Additional amount above rating label amount of Connective pipe lenght Air purging method refrigerant to be charged Less than 5m Use vacuum pump. ------------------------ Liquid side pipe diameter: 5~10m Use vacuum pump. ø 6.35 (Pipe length-5)x30g •...
  • Página 64: Test Running

    TEST RUNNING Perform test running after completing gas leak and electrical safety check. The test running time should last more than 30 minutes. Open the panel and lift the panel up to an angle which remains fixed. Do not lift the panel any fur- ther when it stops with a click sound.
  • Página 66: Belangrijke Opmerking

    BELANGRIJKE OPMERKING: Deze onderhoudshandleiding is bedoeld voor personen die beschikken over voldoende kennis en ervaring op het gebied van elektrische apparaten, elektronica, koeltechniek en mechanische inrichtingen. Pogingen om het apparaat te installeren of te repareren kunnen leiden tot lichamelijk letsel en materiële schade. De fabrikant of verkoper is niet verantwoordelijk voor de interpretatie van deze informatie, en is niet aan- sprakelijk voor een ondoelmatig gebruik van deze informatie.
  • Página 67: Tabla De Contenido

    INHOUD VEILIGHEIDSMAATREGELEN INSTALLATIE VAN BINNEN- EN BUITENUNIT ELEKTRISCHE INSTALLATIE REINIGEN MET LUCHT PROEFDRAAIEN WAARSCHUWING! Installeer, verwijder of herinstalleer de unit niet zelf. • Een ondeskundige installatie kan leiden tot waterlekkage, elektrische schokken, koelmiddellekkage of brand. Raadpleeg voor de installatie een geautoriseerde dealer of specialisten op het gebied van airconditioning.
  • Página 68: Veiligheidsmaatregelen

    VEILIGHEIDSMAATREGELEN Neem altijd het volgende in acht met betrekking tot de veiligheid: • Lees de volgende WAARSCHUWING alvorens de airconditioning te installeren. • Neem de hier genoemde waarschuwingen in acht, aangezien deze belangrijke informatie bevatten met betrekking tot veiligheid. • Bewaar deze instructies, na het lezen ervan, samen met de gebruikershandleiding op een geschikte plaats, zodat u deze documenten gemakkelijk kunt raadplegen.
  • Página 69: Installatie Van Binnen- En Buitenunit

    WAARSCHUWINGEN Installeer de unit niet op een plaats waar brandbaar gas lekt. . • Als gas weglekt en zich verzamelt in het gebied rondom de unit, kan dit leiden tot een ontploffing. Breng de afvoer-/pijpleidingen aan in overeenstemming met de installatie-instructie. •...
  • Página 70: Meegeleverde Onderdelen

    Outdoor unit • Indien er een afdak over de buitenunit wordt gebouwd om blootstelling aan direct zonlicht of regen te voorkomen, dient ervoor te worden gezorgd dat de condensor niet geblokkeerd is. • Zorg ervoor dat de ruimte rond de achterzijde en de linkerzijde van de unit meer dan 30 cm bedraagt. Aan de voorzijde van de unit moet de ruimte meer dan 200 cm bedragen, terwijl bij de aansluitzijde (rechterzijde) een ruimte van 60 cm moet worden aangehouden.
  • Página 71: Installatie Van De Binnenunit

    Ten minste 15 cm Luchtuitlaat Afstandsbediening Bevestigingsschroef B ST 2,9 x 10-C-H Plaats de verbindings- Houder afstandsbediening kabel in een lus WAARSCHUWING • Zorg ervoor dat de ruimte links en rechts van de binnenunit meer dan 12 cm bedraagt. De binnenunit moet zodanig worden geïnstalleerd, dat een minimale afstand tot het plafond van 15 cm wordt aangehouden.
  • Página 72 1. Installatieplaat aanbrengen Breng de installatieplaat horizontaal op structurele delen van de wand aan en houd een ruimte rond de installatieplaat aan. Als de wand is gemaakt van baksteen, beton of een vergelijkbaar materiaal, dienen acht gaten met een diameter van 5 mm in de wand te worden geboord. Breng de verankeringsklem voor de desbe- treffende bevestigingsschroeven aan.
  • Página 73 2. Boor een gat in de wand Bepaal de positie van de gaten aan de hand van het schema in Fig. 5. Boor één gat (65mm) enigs- zins schuin omlaag in de richting van de buitenzijde; dit voorkomt dat er water naar binnen dringt. Maak altijd gebruik van een boorgeleider bij het boren in metalen roosters, metalen platen of verge- lijkbare materialen.
  • Página 74: Leidingwerk Aanbrengen En Omwikkelen

    Bovenste haak Onderste haak Opvulmateriaal Fig. 9 4. Installatie van binnenunit Voer de leiding door het gat in de wand. Breng de bovenste klem aan op de achterzijde van de binnenunit, op de bovenste haak van de instal- latieplaat, beweeg de binnenunit horizontaal om te controleren of deze stevig vastzit. Het leidingwerk kan gemakkelijk worden aangebracht door de binnenunit op te tillen met een opvul- materiaal tussen de binnenunit en de wand.
  • Página 75: Installatie Van De Buitenunit

    INSTALLATIE VAN DE BUITENUNIT Voorzorgsmaatregelen bij buiteninstallatie • Plaats de buitenunit op een stevige ondergrond om ongewenste geluiden en trillingen zo veel moge- lijk te beperken. • Kies de richting van de luchtuitlaat zodanig, dat de afgevoerde lucht niet wordt belemmerd. •...
  • Página 76: Elektrische Installatie

    Sluit de afvoerverbinding aan met een verlenging van de afvoerslang (niet meegeleverd). Zo kan het con- denswater, dat zich vormt in de verwarmingsstand van de airconditioning, worden afgevoerd. Afvoerver- binding Afdichtring Gat in bodem van buitenunit Afdichtring Afvoerpijp Fig. 13 AANSLUITEN VAN DE KOELMIDDELLEIDINGEN •...
  • Página 77: Sluit De Kabel Op De Binnenunit Aan

    Het voedingscircuit moet worden voorzien van een kruipstroombeveiliging met een capaciteit van 1,5 maal de maximale stroomsterkte van de unit. Zorg ervoor dat de airconditioning goed geaard is. Sluit de kabels aan volgens het bijgevoegde elektrisch aansluitschema, dat zich op het paneel van de buitenunit bevindt.
  • Página 78: Reinigen Met Lucht

    Om binnendringen van water te voorkomen, dient de verbindingskabel in een lus te worden aange- bracht, zoals wordt getoond in het installatieschema voor de binnen- en buitenunit. Isoleer ongebruikte snoeren (geleiders) met PVC-tape. Zorg dat deze geen elektrische of metalen delen aanraken.
  • Página 79: Controle Op Elektrische Veiligheid En Gaslekkage

    • Water kan corrosie van onderdelen in het koelsysteem veroorzaken. • Beschadiging van de compressor. Daarom moeten de binnenunit en het leidingwerk tussen de binnen- en de buitenunit altijd worden getest op lekkages en worden leeggepompt met behulp van een vacuümpomp om eventueel aanwezige niet-con- denseerbare stoffen en vocht uit het systeem te verwijderen.
  • Página 80: Proefdraaien

    Controlepunt binnenunit Afdekking Controlepunt buitenunit Fig. 25 PROEFDRAAIEN Na afloop van de gaslektest en de controle op elektrische veiligheid moet het systeem worden proefge- draaid. Til het paneel omhoog totdat het vergrendeld is. Til het paneel niet verder omhoog wanneer het een klikgeluid heeft gegeven.
  • Página 82: Ważna Uwaga

    WAŻNA UWAGA: Niniejsza instrukcja serwisu przeznaczona jest dla osób posiadających znajomość instalacji elektrycznych, elektroniki, chłodnictwa i mechaniki. Wszelkie próby montażu lub naprawy urządzenia mogą spowodować usz- kodzenia ciała i szkody w mieniu. Producent bądź sprzedawca nie ponosi odpowiedzialności za interpretację niniejszych informacji, nie ponosi też...
  • Página 83 SPIS TREŚCI ŚRODKI BEZPIECZEŃSTWA MONTAŻ JEDNOSTKI WEWN TRZNEJ I ZEWN TRZNEJ PRACE ELEKTRYCZNE USUWANIE POWIETRZA PRACA PRÓBNA OSTRZEŻENIE! Nie wolno samodzielnie montować, demontować i/lub ponownie montować klimatyzatora. • Nieprawidłowa instalacja może spowodować wyciek wody, porażenie prądem, wyciek czynnika chłodniczego lub pożar. W sprawie montażu należy skonsultować...
  • Página 84: Środki Bezpieczeństwa

    ŚRODKI BEZPIECZEŃSTWA Ze względów bezpieczeństwa, należy zawsze przestrzegać następujących zaleceń: • Przed montażem klimatyzatora należy konieczne przeczytać poniższe OSTRZEŻENIE. • Należy przestrzegać przestróg podanych w niniejszej instrukcji, ponieważ zawierają one ważne informac- je dotyczące bezpieczeństwa. • Po przeczytaniu niniejszej instrukcji, należy przechowywać ją wraz z instrukcją obsługi w łatwo dostęp- nym miejscu w celu skorzystania z nich w razie potrzeby w przyszłości.
  • Página 85: Jednostka Wewnętrzna

    PRZESTROGI Nie instalować jednostki w miejscu, gdzie występują wycieki łatwopalnego gazu. • Wycieki gazu i jego gromadzenie się w pobliżu jednostki mogą spowodować wybuch. Montaż instalacji odwadniającej / rur prowadzić zgodnie z instrukcją montażu. • W przypadku wystąpienia usterki w instalacji ściekowej / rurach, może nastąpić wyciek wody z jednostki, co może spowodować...
  • Página 86: Jednostka Zewnętrzna

    Jednostka zewnętrzna • Gdy nad jednostką zewnętrzną zbudowany jest daszek mający chronić ją przed bezpośrednim oświetle- niem słonecznym lub przed deszczem należy dopilnować, aby nie utrudniało to odprowadzania ciepła ze skraplacza. • Należy dopilnować, aby odstęp z tyłu i z lewej strony jednostki wynosił ponad 30 cm. Z przodu jednostki należy pozostawić...
  • Página 87: Montaż Jednostki Wewnętrznej

    15 cm lub więcej Wylot powietrza Pilot zdalnego sterowania Wkręt mocujący B ST 2,9 × 10-C-H Uchwyt pilota zdalnego sterowania Zwinąć przewód łączący PRZESTROGA • Należy pozostawić ponad 12 cm wolnego miejsca z lewej i z prawej strony jednostki wewnętrznej. Jednostka wewnętrzna powinna być...
  • Página 88 1. Mocowanie płyty montażowej Przymocuj płytę montażową w pozycji poziomej do konstrukcji nośnej ściany, z zachowaniem odstępów od płyty. Jeśli ściana zbudowana jest z cegły, betonu lub podobnych materiałów, wywierć w ścianie osiem (8) otworów o średnicy 5 mm. Załóż kołki rozporowe , odpowiednie dla wkrętów montażowych Zamocuj płytę...
  • Página 89 2. Wiercenie otworu w ścianie Ustal położenie otworu według schematu przedstawionego na rys. 5. Wywierć jeden (1) otwór (65 mm) pod kątem, lekko w dół, na zewnątrz budynku. Zapobiegnie to wlewaniu się wody do środka. Wykonując otwór w metalowej kracie, płycie, itp. należy zawsze używać rury osłonowej. 3.
  • Página 90 Hak górny Hak dolny Element amorty- zujący Rys. 9 4. Montaż jednostki wewnętrznej Przełóż rurę przez otwór w ścianie. Górny zaczep z tyłu jednostki wewnętrznej nałóż na hak górny płyty montażowej, przesuń jednostkę wewnętrzną w obie strony na boki, aby sprawdzić, czy jest pewnie zawieszona. Podłączenie rur można łatwo wykonać, wkładając element amortyzujący pomiędzy jednostkę...
  • Página 91 MONTAŻ JEDNOSTKI ZEWNęTRZNEJ Środki ostrożności związane z montażem jednostki zewnętrznej • Aby uniknąć wzrostu poziomu hałasu i drgań, jednostkę zewnętrzną należy zamontować na sztywnej pod- stawie. • Ustalić kierunek wylotu powietrza tak, aby nie tamować wypływu powietrza. • W przypadku miejsca montażu wystawionego na silny wiatr, jak np. nad morzem, należy dopilnować, aby wentylator działał...
  • Página 92: Prace Elektryczne

    przewód ściekowy (nie wchodzi w skład dostawy). W ten sposób można odprowadzić skroploną wodę pow- stającą podczas pracy klimatyzatora w trybie grzania. Złącze instalacji Otwór w wanience Uszczelka ściekowej ściekowej jednostki zewnętrznej Uszczelka Przewód ściekowy Rys. 13 PODłąCZANIE PRZEWODóW CZYNNIKA CHłODZąCEGO •...
  • Página 93 W obwodzie zasilania należy zainstalować zabezpieczenie przeciwwypływowe (ziemnozwarciowe) oraz wyłącznik zasilania o obciążalności 1,5-krotnie większej od maksymalnego prądu jednostki. Zapewnić, aby klimatyzator był dobrze uziemiony. Podłącz przewody elektryczne zgodnie z dołączonym schematem połączeń znajdującym się na panelu jednostki zewnętrznej. Cała instalacja elektryczna powinna być zgodna z lokalnymi i krajowymi normami i przepisami elektrycz- nymi i powinna być...
  • Página 94 Aby zapobiec przedostawaniu się wody, należy uformować pętlę na przewodzie łączącym, jak pokazano na schemacie montażowym jednostki wewnętrznej i zewnętrznej. Nieużywane przewody (żyły) zaizolować taśmą PCV. Upewnić się, że nie stykają się one z żadnymi elemen- tami elektrycznymi ani metalowymi. Jednokreskowy schemat instalacji elektrycznej Jednostka zewnętrzna Osłona...
  • Página 95 DłUGOść RURY I ILOść CZYNNIKA CHłODZąCEGO Dodatkowa ilość czynnika chłodzącego, którą należy Długość rury łączącej Metoda usuwania powietrza dodać ponad ilość podaną na tabliczce znamionowej Poniżej 5 m Użyj pompy próżniowej ------------------------ Średnica rury po stronie ciekłej: Ø 6,35 5~10m Użyj pompy próżniowej (Długość...
  • Página 96: Praca Próbna

    PRACA PRóBNA Po sprawdzeniu szczelności instalacji i bezpieczeństwa instalacji elektrycznej należy wykonać uruchomienie próbne. Praca próbna powinna trwać dłużej niż 30 minut. Otwórz panel i unieś go, ustawiając pod kątem, przy którym pozostanie w stałym położeniu. Jeżeli usłyszymy dźwięk kliknięcia i panel zatrzyma się, nie podnosić go dalej. Naciśnij dwukrotnie przycisk sterowania ręcznego, aż...
  • Página 98 +44 1606 837787 tel: +43 7434 44867 fax: +44 1606 837757 fax: +43 7434 44868 email: sales@scottmail.co.uk email: pvgaustria@zibro.com > ITALIA e BELGIË PVG Italy SRL PVG Belgium NV/SA Via Niccolò Copernico 5 Industrielaan 55 50051 CASTELFIORENTINO (FI) 2900 SCHOTEN tel:...