18
UK
9 - DIP SWITCH DIP1
The settings are stored during the rest phase (gate closed).
The default settings are highlighted in the boxes with grey background.
DIP
Function
AUTOMATIC
1_1
STEP-BY-STEP
WITH STOP
TERMINAL 21
AS EDGE
1_2
TERMINAL 21
AS STOP
AMPEROMETRIC STOP
1_3
1_4
SENSITIVITY
1_5
PAUSE TIME
1_6
Status
Operation in response to the START command:
ŸGate closed
ŸDuring opening
ON
ŸGate open
is enabled, otherwise it closes.
Operation in response to the START command:
ŸGate closed
ŸDuring opening
OFF
ŸGate open
ŸDuring closing
ŸAfter a STOP
Operation
:
Ÿ
Gate closed
ŸDuring opening
contact is freed, the gate will continue with inverted movement at low speed.
ON
ŸGate open
ŸDuring closing
contact is freed, the gate will continue with inverted movement at low speed.
Operation :
Ÿ Gate closed
ŸDuring opening
OFF
ŸGate open
ŸDuring closing
OFF
Very High sensitivity.
OFF
OFF
High sensitivity.
ON
ON
Medium sensitivity.
OFF
ON
Low sensitivity.
ON
OFF
Automatic closing disabled.
OFF
OFF
10 seconds.
ON
ON
30 seconds.
OFF
ON
60 seconds.
ON
Description
→
OPENS
→
UNINFLUENTIAL
→
Reloads the automatic closing time if automatic closing
→
OPENS
→
STOPS
→
CLOSES
→
STOPS
→
inverts the motion
→
UNINFLUENTIAL
→
Immediate motion inversion for 2s at low speed, when
→
UNINFLUENTIAL
→
Immediate motion inversion for 2s at low speed, when
→
UNINFLUENTIAL
→
STOP
→
UNINFLUENTIAL
→
STOP
BE12