Special Functions - Nice Moon Instrucciones Y Advertencias Para La Instalación Y El Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 35
L7
Mainte-
L1
nance
L2
warning
L3
L4
L5
L6
L7
L8
L8
List of
L1
faults
L2
L3
L4
L5
L6
L7
L8
Note – The factory settings are highlighted in grey .
01. Press and hold down the "Set" key for approx . 3 seconds .;
02. Release the key when LED "L1" starts flashing;
03. Press the "" or "" key to move the flashing LED to the LED representing the "input LED" of the parameter to be modified;
04. Press and hold the "Set" key through to completion of point 06;
05. Wait approx . 3 seconds, until the LED representing the current level of the parameter to be modified illuminates;
06. Press keys "" or "" to move the LED representing the value of the parameter;
07. Release the "Set" key;
08. Wait 10 seconds (maximum time) to exit the programming mode .
Note – During this procedure, points 03 to 07 need to be repeated when programming other parameters during the phase itself .

5.3 - Special functions

5.3.1 - Function: "Move anyway"
This function allows the automation to be operated even when any of the safety
devices does not work correctly or is out of use .
The automation can be controlled in the "hold-to-run" mode . Proceed as follows:
01. Send a command to operate the gate using a transmitter or a key selector,
etc . If everything operates correctly, the gate will move normally, otherwise
proceed as follows;
02. within 3 seconds, activate the control again and keep it activated;
03. after approximately 2 seconds, the gate will perform the required movement
in "hold-to-run" mode; i .e . the gate will continue to move only as long as
the control is activated .
If the safety devices do not operate, the flashing light flashes a few times to indi-
cate the kind of problem (see chapter 6 - Table 10) .
5.3.2 - Function: "Maintenance warning"
This function serves to indicate when the automation requires maintenance.
The maintenance warning signal is given by way of a lamp connected to the
S .C .A . (open gate light) output when this output is programmed as "Maintenan-
ce light" . The various warning lamp signals are shown in Table 9 .
Table 9 - "Maintenance light"
Number of manoeuvres
Signal
Below 80% of the limit
Light on for 2 seconds at the start of the opening
manoeuvre .
Between 81% and
Light flashing for the entire duration of the manoeuvre .
100% of the limit
Beyond 100% of the limit
Light flashing continuously .
To program the limit value of the maintenance operations, see Table 8 .
500
1000
1500
2500
5000
10000
15000
20000
Manoeuvre 1 result (most recent)
Manoeuvre 2 result
Manoeuvre 3 result
Manoeuvre 4 result
Manoeuvre 5 result
Manoeuvre 6 result
Manoeuvre 7 result
Manoeuvre 8 result
TABLE 8 – Programming procedure (second level functions)
5.4 - Deleting the memory
To delete the control unit memory and restore all factory settings, proceed as
follows: press and hold keys "" and "" until leds L1 and L2 start flashing .
Controls the number of manoeuvres:
when this number is exceeded, the
control unit signals an automation
maintenance request; see paragraph
5 .3 .2 . – Maintenance warning .
The type of fault that has occurred in
the last 8 manoeuvres can be esta-
blished
See TABLE 12 – Fault log .
SET
3 s
SET
L1
or
SET
or
SET
10 s
English – 7

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Mc824h

Tabla de contenido