Schulz S1200MG Manual De Instrucciones página 93

Generadores gasolina-diesel
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

ATTENTION:
up the generator. In this case, after the switch is turned on/off, the starter motor can remain connected even
after turning the device off, remaining in this condition until consuming all the remaining battery charge. To
avoid this, always keep the generator's battery at full charge. This can be performed basically in two ways:
1. Turning on the generator periodically, every week, keeping it running for at least 30 minutes to charge the
battery;
2. Externally charging the battery, using an appropriate charger (e.g. Schulz 12V charger).
IMPORTANT
the situation.
Note: The maintenance recommendations described in this manual are aimed at regular operation conditions. If
your generator works under severe use conditions, such as high electricity load for long periods, high temperatu-
re, humid places or dusty places, consult the manufaturer or an authorized assistant to obtain recommendations
about your individual needs.
ATTENTION:
of the generator, and thus cause accidentes in which the user might be seriously hurt or even die. Follow the
maintenance described in this manual correctly.
7. Procedure for changing engine oil:
Remember to drain the oil while the engine is hot to guarantee total removal of the used oil.
Procedure of changing:
A. Remove drain plug, seal washer and the measuring rod and let the oil flow into an adequate container;
B. Reinstall the plug and the seal washer tightening until a good fixation is guaranteed.
C. Fill tray in with the oil specified in this manual (SAE 20W 50) up to the specified level.
WARNING: Used oil might cause skin cancer if in prolonged contact. It is recommended to wash hands with
water and soap everytime you handle used oil.
Oil must be discarded in an appropriate way. Under no circumstances in domestic trash. Discard used oil and
the items contaminated with the oil according to local norms and take it to recycling centers.
If the battery is low on charge (voltage below 12Vdc), failure can occur when starting
For long or repetitive periods of use, draw up a special maintenance plan according to
Improper maintenance or failure in solving any problem might result in bad working
OIL DRAIN PLUG
UPPER LEVEL
OIL FILLER CAP
FIGURE 9.1
93

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

S2500mgS3500mgS5500mgS8000mgS12000mgS5000td ... Mostrar todo

Tabla de contenido