Descargar Imprimir esta página

Zipro Flame Manual De Uso página 38

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 241
TROUBLESHOOTING
CAUTION! Opening the housing of the device without a prior contact with a manufacturer's service
voids the warranty. If you suspect a failure that requires the housing to be opened, contact manufacturer's
service.
Error description
The device rocks to sides
The saddle or handlebar sway
Noise during use
Noise and uneven operation
Lack of appropriate
resistance during training
No Bluetooth
connection
E-1
E-2
E-4
E-7
Possible causes
The device was placed on an uneven
surface.
There is an object disrupting the
balance under the base of the device.
The bases have not be assembled
correctly.
Caps on the base have not been
installed and levelled correctly.
Bolts and knobs of the saddle
column or handlebar column have
not been tightened.
Incorrectly tightened elements.
Slight humming noise may be heard during operation due to the inertial
movement of the flywheel caused by the nature of the structure. It does not
affect the operation of the device. Any possible humming noises heard when
rotating the pedals backwards occur for technical reasons and have no
negative consequences.
Bearings damaged.
Resistance adjustment cable
connected incorrectly.
Drive belt loose.
The distance between
the flywheel and
the magnets increased.
Voltage regulator
damaged.
Bluetooth connectivity issues.
The device receives no input while
measuring the user's body fat.
Power system error.
The numerical scale was exceeded
when reporting the age, height, or
weight of a user.
The cables connecting the console to
the bike have become disconnected
or are not connected properly.
Solution
Place the device on an even surface.
Remove the object that upsets the
balance.
Assembly the bases correctly.
Level the caps on the rear base.
Assembly the rear base correctly.
Level the caps on the rear base.
Tighten the bolts and knob of the
saddle or handlebar column.
Contact the manufacturer's service.
Contact the manufacturer's service.
Connect the cable correctly as per
the assembly manual.
Contact the manufacturer's service.
Contact the manufacturer's service.
Contact the customer service of the
manufacturer's service.
Enable Bluetooth on your mobile
device. Pair your mobile device with
ZIPRO.
Keep both hands on the pulse
sensors during the measurement.
Contact the manufacturer's service.
When entering user data, provide
data that fit the scale.
Disconnect the power source, then
disconnect the cables. Reattach the
cables and power source. If the error
occurs again, repeat the process.
EN
38

Publicidad

loading