2.4
2.4.3 Special manufactures
2.4.3 Special manufactures
Motor mounting interfaces
In addition to the standard mounting
arrangements shown in chapter 2.1, motors
are also available mounted with pads for
anchorage to a pipe or ventilation system.
GB
Table 2 F
Frame
Structural
size
56
63
71
80
16
Special flanges
Motors are available with flanges other than
standard flanges which comply with
NFC 51-120 regulations, with through holes
(B5) or threaded holes (B14).
The table below, in addition to the figures
given in chapter 5 (Overall dimensions),
gives the measurements of the available
flanges.
Flange
form
B5
FF85
B5
FF115
B14
FT75
B5
FF100
B14
FT65
B5
FF130
B14
FT85
B5
FF100
B14
FT65
B5
FF115
B14
FT75
B5
FF165
B5
FF115
B5
FF130
B14
FT85
B5
FF215
Dimensions [mm]
Ø M
Ø N
85
70
115
95
75
60
100
80
65
50
130
110
85
70
100
80
65
50
115
95
75
60
165
130
115
95
130
110
85
70
215
180
Ø P
Ø TLB
105
7.0
140
9.0
90
---
120
7.0
85
---
160
9.0
105
---
120
7.0
85
---
140
9.0
90
---
200
11.0
140
9.0
160
9.0
105
---
250
13.5
Ø TTB
---
---
M5
---
M5
---
M6
---
M5
---
M5
---
---
---
M6
---