CEBORA S.p.A.
NOTE: If the pump turns with no coolant present, you must remove all air from the tubes:
- shut off the Power Source and fill the tank;
- disconnect the blue tube of the Power Source - Wire Feeder extension (2) from the fitting BT;
- connect one end of a new tube to the free fitting BT and insert the other end of the pipe in the
tank;
- run the Power Source and then the Cooling Unit for approximately 10/15 seconds to fill the
pump;
- shut off the Power Source and reset the tube connections of the Power Source - Wire Feeder
extension (2).
4
POWER SOURCE.
The Power Source does not work independently, but must be connected to the other system equipment.
The Power Source is the main power supply of the Welding System and provides the supply voltages to
all other equipments.
The equipments may be used only for the purposes described in the present manual.
4.1
Technical specifications.
IEC 60974.1
The Power Source is built according to the following international standards.
EN 50199
N°.
Serial number. Must be indicated on any request regarding the Power Source.
Three-phase static frequency converter
Transformer - rectifier.
MIG
Suitable for MIG/MAG welding.
MMA
Suitable for welding with covered electrodes.
TIG
Suitable for TIG welding.
U0.
Secondary open-circuit voltage.
X.
Duty cycle percentage. The duty cycle expresses the percentage of 10 minutes during
which the Power Source may run at a certain current without overheating.
I2.
Welding current.
U2.
Secondary voltage with I2 current.
U1.
Rated supply voltage.
3~ 50/60Hz
50 / 60-Hz three-phase power supply.
I
Max
Max. current absorbed at the corresponding current I
1
I
eff
This is the maximum value of the actual absorbed current considering the duty cycle. This
1
value usually corresponds to the capacity of the fuse (delayed type) to be used as a
protection for the equipment.
IP23 C
Protection rating for the housing. Grade 3 as the second digit means that this equipment is
suitable for use outdoors in the rain. The additional letter C means that the equipment is
protected against access by a tool (Ø 2.5 mm) to the live parts of the power supply circuit.
Suitable for use in high-risk environments.
NOTE: The Power Source has been designed for work in environments with pollution rating 3 (See IEC
664).
3300305-B
Temperature
water/alcohol.
0°C up to -5°C
-5°C up to -10°C
4L/1L
3.8L/1.2L
and voltage U
.
2
2
15
GB
18-03-2016