Cap
DC Sensor
Connector
Retaining Nut
Solenoid
Connector
Pin
Diaphragm

Install the Solenoid

Align the solenoid with the hole in the piston cover, then set it
into place.
NOTICE: Do not overtighten the solenoid. Damage to the solenoid
can occur.
Using an adjustable wrench, turn the solenoid clockwise to
tighten it.
Connect the DC sensor connector to the solenoid connector.
Locate the connector assembly next to the sensor body to avoid
pinching.
NOTICE: Ensure that the solenoid wires are not caught between the
cap and the valve body.
Place the cap on the valve body, then secure with the setscrew.
Open the control stop valve.
Verify the valve functions.