15) Vacuum bottle cap.
Allows vacuum packing of bottled liquids
Chapter 5. Safety instructions
5.2. Accessories
Check the following is present inside the packaging:
MX 2
MX 4
8)
Pouch support
8)
Table
8.1) Corner to position pouches
16) Fitting for external vacuum
9)
Pouches for freezing, cooking and storage
17) 2.5 mm Allen key
(N. 15 20x30 cm + N. 15 25x35 cm)
10) Power cable
11) Pump filter
(to be fitted before use. See attached
instructions)
12) Chute for draining used pump oil
13) Pump oil filter mounting spanner
14) Hose kit + fittings for external vacuum.
5.3. Environmental conditions
Allows you to connect the equipment to the
Lift the machine and place it on the working surface. Make sure the machine is placed in a proper environment without
container and/or bottle that you want to
any inflammable and explosive materials or gas. The machine may only be installed on smooth, flat non-inflammable
vacuum-pack
surfaces.
15) Vacuum bottle cap.
Allows vacuum packing of bottled liquids
Working environmental conditions:
Temperature from + 5°C to + 40°C.
Relative humidity from 30% to 90%, without condensation.
The lighting of the operation room shall comply with the laws in force in the country where the machine is installed.
However, it shall be uniform and provide for good visibility in order to safeguard the operator's safety and health.
MX 4
MACHINE SAFETY FACTOR = IP20
THE AERIAL NOISE MADE BY THE MACHINE IS LOWER THAN 70 dB(A)
Chapter 5. Safety instructions
8)
Table
16) Fitting for external vacuum
5.5. Electrical connection
17) 2.5 mm Allen key
5.4. Intended use
MX
2: Household and commercial use
MX
4: Commercial use
Risk of fire and electric shock.
Both models cannot be used in a garage.
All the electrical connections must be made by a qualified electrician.
The appliance must be earthed.
Do not use multi-plug adapters or extension cables.
5.3. Environmental conditions
Connect the mains plug to the mains socket only once installation has been completed.
Lift the machine and place it on the working surface. Make sure the machine is placed in a proper environment without
Do not connect the mains plug if the mains socket is loose.
any inflammable and explosive materials or gas. The machine may only be installed on smooth, flat non-inflammable
Do not pull the mains cable to disconnect the appliance. Pull only the mains plug.
surfaces.
Make sure that all the electrical data shown on the data plate correspond to those of the system.
Working environmental conditions:
Otherwise, contact an electrician.
Temperature from + 5°C to + 40°C.
Relative humidity from 30% to 90%, without condensation.
Note: when contacting the Manufacturer, always indicate the model and the serial number
specified on the plate on the rear part of the machine.
The lighting of the operation room shall comply with the laws in force in the country where the machine is installed.
However, it shall be uniform and provide for good visibility in order to safeguard the operator's safety and health.
MACHINE SAFETY FACTOR = IP20
The power line must be protected with a type A residual current device with rated residual current equal to
THE AERIAL NOISE MADE BY THE MACHINE IS LOWER THAN 70 dB(A)
"IΔn", 30 mA.
As a result, the maximum resistance of the earth electrode must correspond to the values indicated in the
following table.
5.4. Intended use
IΔn
Maximum resistance of the earth electrode
MX
2: Household and commercial use
(50 V)
MX
4: Commercial use
16 Ω
3 A
Both models cannot be used in a garage.
1 A
50 Ω
500 mA
100 Ω
166 Ω
300 mA
30 mA
1666 Ω
5.6. Use
Risk of injury, burns, electric shock or explosion.
33
(25 V)
8 Ω
25 Ω
50 Ω
83 Ω
833 Ω
33
7/7