5) F - FREQUENCY BAND SELECTION
See § FUNCTIONS TURNING ON THE UNIT page 47.
6) ANL/NB ~ HI-CUT ~ SKIP
ANL/NB
(short press)
A short press on the ANL/NB key (6) allows you to
the following settings: no filter (default) / ANL activated
/ ANL and NB activated.
The icon of the active filter appears on the display.
Warning: ANL filter works only in AM mode
HI-CUT
(long press)
A long press on the HI-CUT key (6)
(defaults) the HI-CUT filter. When the filter is activated
"HI-CUT"appears on the display.
HI-CUT: Cuts out the high frequency interferences and has
to be used in accordance with the reception conditions.
When active, the filter is displayed on display.
SKIP
(long press only if the SCAN function is activated)
This function allows you to
SCAN function. When the scan stops on an unwanted
channel, press and hold the ANL/NB key (6) for 1 second
to
store
this channel in the SCAN SKIP memory. A beep
sounds. The channel will no longer be scanned. See the
§ SCAN page 44.
Consult the SCAN SKIP menu page 49.
7) AM/FM ~ VOX SET
activate
activate/deactivate
skip
a channel found by the
AM/FM
(short press)
The AM/FM key (7) allows you to
mode AM or FM. Your modulation mode has to corre-
spond to the one of your correspondent. Selected mode
is displayed on the LCD.
Amplitude Modulation / AM: communication on a field
with relief and obstacles at middle distance (the most
used).
Frequency Modulation / FM: for nearby communications
on a flat open field.
In U configuration ONLY: press AM/FM key (7) to alter-
nate the frequency band between ENG and CEPT. "UK"
appears in the display when the ENG band is selected.
"UK" disappears on the display when CEPT is selected
(see table at page 71).
VOX SET
(long press)
Three parameters allow to adjust the VOX function:
Sensitivity:
/ Anti-vox level:
.
Long press the VOX key (7) to
function. The message show the current parameter :
or
.
1. Press then VOX key (7) to
2.
Press the UP/DN key on the microphone or the s/t key
(3) on the unit to
change
3. Once the settings done, press the PTT switch (11) to
and
exit
the VOX Adjustment mode. If no adjustment
is made for 5 seconds, the unit automatically
mode without saving.
45
select
the modulation
/ Vox delay time:
enter
in the VOX Adjustment
select
the next parameter or...
the value of the parameter.
exits
,
save
the

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Txpr101

Tabla de contenido