• Inspect the pumping station to make sure there is no damage due
to transport.
2.3 TEMPORARY STORAGE / PACKAGING
• The machine can be kept in interim storage and conserved in a cool,
dark, dry and frost-free site.
• The systems should stand in horizontal position.
• In the case of commissioning after an extended storage period, take
the following precautions to ensure storage of the pumping station:
NOTICE
Wet, dirty or damaged openings and junction points.
Leaks or damage to the pumping station!
Clear the pumping station's blocked openings at the
time of installation.
2.4 DISPOSAL
The device must not be disposed of as household waste and
must be disposed of at a recycling point for electrical equip-
ment. The device's materials and components are reusable.
The disposal of electrical and electronic waste, recycling and
recovery of any form of used appliances contribute to the
preservarion of our environment.
3. DESCRIPTION
3.1 GENERAL DESCRIPTION
The effluent lifting stations Sanicubic GR are single or double systems
that are ready to plug in and safe against flooding, with collection
chambers made of gas- and odour-proof plastic. They work with ver-
tical cutting unit pumps with automatic pneumatic level control. They
are completely equipped with switch boxes and all necessary swit-
ching elements.
3.2 APPLICATIONS
The effluent lifting units of the Sanicubic GR production series are
used for the disposal (collection and conveying) of domestic effluent
that develops underneath the canal backflow level.
The following liquids/substances are not allowed in discharge sys-
tems:
– Solid materials, fibres, tar, sand, cement, ash, coarse paper, hand
towels, wipes, cardboard, rubble, rubbish, slaughterhouse waste, oils,
greases, etc.
– Wastewater containing harmful substances (for example, untreated
greasy waste from restaurants). Pumping these liquids and subs-
tances requires the fitting of a compliant grease trap.
3.3 OPERATING PRINCIPLE
The wastewater flows by gravity into the Sanicubic GR lifting station.
The collecting tank is designed for non-pressure operation. Wastewa-
ter is collected there at atmospheric pressure before being discharged
to the sewer.
The water rising in the tank compresses the air in the dip tube screwed
to the top of the tank. When the preset switch-on height is reached,
the pump is activated and pumps the water out of the tank via the
discharge line. A non-return ball valve (two in double systems) pre-
vents the water from flowing back from the discharge line into the
tank.
For double pumps models, both pumps operate each in turn, alterna-
tely. In case of abnormal operation, both engines run simultaneously
(or if one pump fails, the other takes over).
The control box is equipped with an audible alarm that is activated
in case of pump(s) failure or if the water level in the tank is too high.
External alarm devices can be connected to the terminal blocks pro-
vided (refer to the control box manual). Their location is indicated on
the wiring diagram of the switchgear.
3.4 SCOPE OF SUPPLY
The sewage lifting stations of the Sanicubic GR series are supplied
with:
– built-on macerator pump(s) of the Sanipump® ZFS 71 series,
– connection for emergency drainage or manual diaphragm pump,
– pneumatic control and control box
– flexible connection for venting the collection chamber
137 kg
150 kg
144 kg
160 kg
– pressure outlet connection DN 32
– non-return ball valve(s) DN 32
– Y-pipe DN 32/50 (only for double system).
3.5 TECHNICAL DATA
SANICUBIC GR 1
SE71.1 S
SANICUBIC GR 2
Power P1 (kW)
2.2
Power P2 (kW)
1.7
Voltage U (V)
230
Maximum
absorbed current
10.5
(A)
Rated speed at 50
2800
Hz (n-1)
IP code
IP 68
Max. flow rate
17
(m
/h)
3
Max. discharge
height
22
(m)
Max. temperature
of the pumped
liquid
Operating mode
Sanicubic GR 1
Discharge
diameter
Inlets diameter
Inlets Height
h (mm)
Sanicubic GR 2
Discharge
diameter
Inlets diameter
Inlets Height
h (mm)
Material
Tank
PE LD
Pump housing
GG-20
Motor housing
GG-20
Valve
GG-20
3.6 CURVE
3.7 OVERVIEW
See pg. 23.
3.8 DIMENSIONS
See pg. 8.
4. INSTALLATION
4.1 PREPARATION
• The characteristics shown on the rating plate have been compared
with those on the order and installation (supply voltage, frequency).
• The installation room must be protected against frost.
• The installation room is adequately lit.
• The work has been prepared in accordance with the standard
EN 12056-4.
• The plant room where the Sanicubic will be installed must be large
enough to allow a 600 mm clearance around and above the device to
facilitate maintenance. The height of the room should be approxima-
tely 2 to 2.5 m.
• The alarm signal is always visible to the user (if necessary, use an
external alarm contact switch).
• In case of discharge of greasy effluents, the use of a degreasing tank
is essential.
18
SE71.1 T
SE71.2 T
SE71.3 T
2.1
2.1
3.9
1.7
1.7
3.2
400
400
400
3.7
3.7
6.5
2800
2800
2800
IP 68
IP 68
IP 68
17
17
17
22
25
35
55°C
S3 25%
1-1/4"
DN50, DN100
250 (back and side inlets)
576 (upper inlet)
DN50
DN50, DN100, DN150
250 (back and side inlets)
586 (upper inlet)
Impeller
GG-20
Shaft
Stainless steel
Pipework
Stainless steel
Seals
Carbone/Céramique
SE71.4 T
3.9
3.2
400
6.5
2800
IP 68
17
39