PROBLEM
CAUSE
Compressor is
Prolonged excessive
not supplying
use of air.
enough air
Compressor is not large
to operate
enough for air requirement.
accessories
Hole in hose.
Check valve restricted.
Air leaks.
Restricted air intake filter.
Loose belt.
Restricted
Dirty air filter.
air intake
Motor will
Motor overload protection
not run
switch has tripped.
Tank pressure exceeds
pressure switch "cut-
in" pressure.
Check valve stuck open.
N003195
All manuals and user guides at all-guides.com
CORRECTION
Decrease amount of air usage.
Check the accessory air
requirement. If it is higher than
the SCFM or pressure supplied
by your air compressor, you
need a larger compressor.
Check and replace if required.
Remove and clean, or replace.
Tighten fittings.
Clean or replace air intake filter.
Do not operate the air compressor
with the filter removed. Refer
to the Air Filter paragraph in
the Maintenance section.
Loosen wingnut and then
tighten wingnut until it contacts
the washer, plus one turn.
Clean or replace. See Air
Filter paragraph in the
Maintenance section.
Refer to Motor Overload Protection
under Operation. If motor overload
protection trips frequently, contact
a Trained Service Technician
Motor will start automatically when
tank pressure drops below "cut-
in" pressure of pressure switch.
Remove and clean, or replace.
22 - ENG