Model No.
Running Horsepower
Voltage/Hertz/Phase
Minimum Branch Circuit Requirement
Fuse Type
Air Tank Capacity (Gallon)
Approximate Cut-in Pressure
Approximate Cut-out Pressure
SCFM @ 40 PSIG
SCFM @ 90 PSIG
*Tested per ISO 1217
Refer to Glossary for abbreviations.
Become familiar with these terms
before operating the unit.
CFM: Cubic feet per minute.
SCFM: Standard cubic feet per minute;
a unit of measure of air delivery.
PSIG: Pounds per square inch gauge;
a unit of measure of pressure.
Code Certification: Products that bear
one or more of the following marks: UL,
CUL, ETL, CETL, have been evaluated
by OSHA certified independent safety
laboratories and meet the applicable
Standards for Safety.
Cut-In Pressure: While the motor is
off, air tank pressure drops as you
continue to use your accessory. When
the tank pressure drops to a certain low
This air compressor pump is capable
of running continuously. However, to
prolong the life of your air compressor,
it is recommended that a 50%-75%
Accessories for this unit are available
at the store the unit was purchased.
N003195
All manuals and user guides at all-guides.com
SPECIFICATIONS
CPLC7060V
*3.0
240V/60/1
15 Amp
Time Delay
60 ASME, Vertical (227.1 liters)
110 PSIG
135 PSIG
*12.1
*9.7
GLOSSARY
level the motor will restart automati-
cally. The low pressure at which the
motor automatically restarts is called
"cut-in" pressure.
Cut-Out Pressure: When an air com-
pressor is turned on and begins to run,
air pressure in the air tank begins to
build. It builds to a certain high pres-
sure before the motor automatically
shuts off - protecting your air tank from
pressure higher than its capacity. The
high pressure at which the motor shuts
off is called "cut-out" pressure.
Branch Circuit: Circuit carrying elec-
tricity from electrical panel to outlet.
To Lock Out Power: Place a lock on
the line power switch so no one else
can turn on the power.

DUTY CYCLE

average duty cycle be maintained; that
is, the air compressor pump should not
run more than 30-45 minutes in any
given hour.
ACCESSORIES
accessory not recommended for use
with this tool could be hazardous.
Use only accessories rated equal to
or higher than the rating of the air
compressor.