Do not use indoors.
Do not exceed a height of 2135m above sea level.
Make sure that the ambient temperature is between
+40 and -25 ° C and that the relative humidity does
not exceed 90%.
! The generator must be grounded to prevent electric
shock. Use an insulated wire to connect the generator
ground connection and the external ground.
It is necessary that the connection of the generator
to the el. network and grounding by an authorized
person.
Improper connection between the generator and the
appliance can cause damage to the generator, or fire
or injury.
SAVE THESE SAFETY INSTRUCTIONS !!!
DESCRIPTION
1. Fuel tank
2. Handle
3. 230 V ~ socket
4. Fuel cock
5. Choke lever
6. Overload protection - DC
7. Power switch
8. Starter handle
9. Fuel tank cap
10. DC voltage output
11. Air filter
12. Oil drain plug
13. Oil tank cap
14. Grounding
15. Alternator
16. Muffler
17. Indicator light
18. Voltmeter
19. Spark plug
Pictograms
Pictograms on the product packaging:
a) Power supply values
b) Maximum power
c) Continuous performance
d) Engine idling speed
e) DC voltage output
f) Fuel tank volume
g) Engine displacement
h) Weight
i) Max. altitude
j) Protection class - Type of protection

USE AND OPERATION

ASIST devices are intended for home or hobby use
only.
The manufacturer and importer do not recommend
using this device in extreme conditions and under
high loads.
Any additional requirements must be the subject of
an agreement between the manufacturer and the
customer.
ATTENTION! Check the oil level and
fuel level before using the generator.
The safety system will prevent the
generator from starting if the oil level
and fuel level are not correct.
Before use
! The generator must be grounded to prevent electric
shock. Use an insulated wire to connect the generator
ground connection and the external ground.
-! Use only unleaded petrol (Natural 95) as fuel.
-! Use high quality engine oil for high speed petrol
engines, with a viscosity of SAE10 / 30.
Quality oils save your equipment and the environ-
ment.
Using poor quality oil can damage the generator. If
the engine is damaged due to the use of incorrect lub-
ricant, any claim cannot be accepted as justified.
Check fuel level and top up if necessary.
! Ensure adequate ventilation of the device and check
the surroundings of the generator.
Make sure the ignition cable is attached to the spark
plug.
! If any electrical equipment is connected to the gene-
rator, disconnect it.
The device is delivered without oil.
„Before commissioning, top up with oil with a viscosity
of SAE 10/30. E.g. M6A, M6AD.
Check oil level
-! Before checking the oil, switch off the generator and
place it on a level surface.
- Pull out the measuring cup and clean it with a cloth.
- Insert the clean measuring cup back into the hole.
Pull it out and check the oil level.
- The oil level must be between the maximum and
minimum limits on the dipstick. If necessary, add oil
slowly and check the level. Top up the oil to the ma-
ximum level.
- Push the measuring cup back in and seal it.
Fuel level
Open the fuel cap.
Check fuel level. If there is not enough fuel in the
tank, refuel.
Fresh fuel prevents the formation of a coating in the
fuel system. Do not leave fuel in the tank for more
than 30 days.
! Make sure that dust, water and foreign objects do
not get into the fuel tank.
Pour fuel through the filter / strainer.
Close the fuel tank.
57