8 h
25 h
A
B1
X
B2
X
C
D
E
F
X
G1
X
G2
H
X
I
J
X
K
L
After the first 10 hours of operation, a complete
inspection of the device and cleaning of all filters is
required.
(oil, fuel, spark plug, fuel line, filters, joint strength)
Possible defects
The following problems may occur during operation:
Gasoline generator does not start:
If the engine does not start, try the following:
1. Check fuel level. (Turn the fuel cock (4) to the „ON"
position)
2. Turn the engine switch (7) to the „ON" position.
3. The spark plug is dirty from carbon or damp - re-
move the carbon or wipe the spark plug dry.
4. Check that the fuel supply (fuel tap) is not blocked.
5. If the starter handle speed is not developed
enough.
6. Foreign body in the fuel cap - clean the fuel cap.
7. Carburetor clogged - clean the carburetor.
8. Oil level is low - top up engine oil.
9. Defective ignition system, Worn piston and cyl-
inder, Loose cylinder nuts, Damaged seal - consult
dealer or dealer. authorized service.
! If the engine still cannot be started, do not attempt
to repair the generator, but take it to an authorized
service center.
The petrol generator does not supply voltage
1. Check that the AC / DC protection is in the „ON"
position.
2. Check that the device has been connected cor-
rectly to the generator.
3. Unplug the device.
Contact an authorized service center
Generator transmission and storage
When transferring the generator, turn the genera-
tor switch and fuel cock to the „OFF" position. Hold
the generator to prevent fuel spillage. Fuel fumes or
spilled oil can ignite.
Contact with a hot part or exhaust system can cause
severe burns or fire. Allow the device to cool before
Check all accessories and
L
fasteners.
Repair them if necessary.
50 h
100 h
300 h
X
X
X
X
X
X
X
X
X
transferring and storing.
When transferring, be careful not to drop the device
or strike it with anything. Do not place heavy objects
on the generator.
Store the generator in a well-ventilated area with an
empty fuel tank.
CAUTION: If you want to store the generator for an
extended period of time, you must perform the follow-
ing procedure:
Drain the fuel tank and carburetor float chamber. Pour
a little engine oil into the tank.
Shake the tank. Drain excess oil.
Fill the lubricating oil up to the maximum mark on
the oil dipstick. Using a hand starter, turn the engine
several times (with the ignition off). Pull out the hand
starter until you feel resistance.
Stop pulling.
Clean the outside of the generator and apply an
anti-corrosion agent. Store the generator in a dry,
well-ventilated place and cover it. The generator must
remain horizontal
SPECIFICATIONS
Engine type
single-cylinder, 4-stroke, air-cooled
Rated power 2000 W
Maximum power 2200 W
Output voltage 230 V / 1 ~
Frequency 50 Hz
Engine idle speed 3,000 rpm
DC output 12 V / 8.3 A
Engine displacement 163 cm3
Spark plug type F6TC
Unleaded petrol (octane number 95)
Fuel tank volume 15 l
Fuel consumption 1.15L / h
Continuous operation time 13 hours
Weight 40 kg
Degree of protection IP IP 23
Protection class I.
Sound pressure level measured according to EN
60745:
LpA (sound pressure) 65 dB (A) KpA=3
LWA (sound power) 77 dB (A) KwA=3
Take appropriate measures to protect your hearing!
Wear hearing protection whenever the sound pressure
exceeds the level of 80 dB (A).
Weighted effective acceleration according to EN
60745:
6,94 m/s2 K=1.5
Caution: The vibration level may vary during power
tool operation from the declared value depending on
the way the power tool is used and depending on the
following conditions: Method of power tool use and
type of material being cut or drilled, conditions of the
power tool and method of its maintenance, appro-
priateness of the used accessories and ensuring its
sharpness and good conditions, the strength of handle
60