Overload indicator (red)
When the overload indicator is on, it indicates
that the generating set is overload and then the
AC protector works. It will stop the output of
generating set to protect the electric equipment
and the generating set itself. At this time, the
running indicator (green) is off and the overload
indicator (red) is on, but the engine is still in
running state.
When the generating set has no output and the
overload indicator is on, please take the
following steps:
Lower the total power of the connected
1.
electric devices to the rated output range of
generating set.
Check the air intake for impurities and
2.
check the control parts for abnormal
situation. Handle immediately if necessary.
Press the reset button.
3.
Running indicator (green)
The running indicator lights up when generating set
starts and has normal output.
Oil alarm lamp (yellow)
When the oil level drops below the lower limit, the oil
protection system will stop the engine automatically
and oil alarming lamp will blink by pulling the recoil
starter. The engine will not run until the oil has been
filled to the proper level.
Note: If engine flames out or fails to start, turn the
combination switch to "RUN" position and then pull
the recoil starter. If the oil alarming lamp lights up, it
shows lack of oil. Please add appropriate oil and
restart the engine.