VI. Storage and transportation
Storage
The generating set should be started at least once
every 2 weeks and allowed to run for at least 20
minutes. Follow the instructions below for longer
term storage if the generating set will be out of service
for 2 months or more.
Fire or explosion
Gasoline is highly flammable and extremely
explosive.
Empty the fuel tank and shut off fuel valve before
storing or transporting this generating set.
1.
Allow the generating set to cool completely
before storage.
2.
Clean the generating set according to
instructions in Maintenance section.
3.
Drain all fuel completely from the fuel tank,
fuel hose and carburetor to prevent gum from
forming.
4.
Turn the combination switch in "STOP"
position to cut off the fuel.
5.
Remive the oil drain plug to drain out the oil
(See steps c, d, e at page 23).
6.
Remove the spark plug and pour about 15 ml of
fresh oil into the cylinder. Pull the recoil starter
slightly to distribute the oil and lubricate the
cylinder. And then attach the spark plug.
7.
8.
Transportation
When generator transportation or short term
storage, the generator should be in the normal
operating position and fixed vertically to
prevent fuel leakage. The combination switch
should be in the "stop" position and knob of the
DANGER
fuel cap should be turned to the "OFF" position.
When transporting:
Do not overfill the tank. Do not operate the
generating set while it is on vehicle.
Take the generating set off the vehicle and use
it in a well-ventilated place. Avoid a place
exposed to direct sunlight when putting the
generating set on a vehicle. If the generating
set is left in an enclosed vehicle for many
hours, high temperature inside the vehicle
could cause fuel to vaporize resulting in a
possible explosion. Do not drive on a rough
road for an extended period with the
generating set on board. If you must transport
the generating set on a rough road, drain the
fuel from the generating set beforehand.
33
Store the unit in a clean, dry area out of
direct sunlight.
please disconnect the battery.
WARNING

Publicidad