Choke lever
Note: when cold start, please close (pull) the choke
lever. When warm start, please open (push) the
choke lever.
Energy-saving switch
When the energy-saving switch is in "ON" position,
the energy saving equipment controls the engine
rotate speed according to the connected loads. There
will be good fuel consumption and low noise.
When the energy-saving switch is in "OFF"
position, the engine will always run in rated rotate
speed no matter it is connected to the loads or not.
Note: Please set the energy-saving switch to "OFF"
position when connect to air compressor, sinking
pump etc., because these equipments need large
starting current.
Grounding terminal
The grounding terminal is designed to prevent
electric shock by connecting it to the grounding
wire. The generating set must be properly grounded
before operation.
Two-in-one switch
(engine stop & fuel switch)
When the switch is in "OFF" position, it indicates
that the engine stop switch and fuel switch are in off
state.
When the switch is in "RUN" position, it indicates
that the engine stop switch and fuel switch are in on
state.
Reset button
The reset button is used to restore output if an
overload occurs. To restore output, reduce the loads
and press the reset button.