Descargar Imprimir esta página

MAHLE X20 System Guia Del Usuario página 28

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 30
DISCHARGE_OVERCURRENT
222
The RE has suffered an overcurrent. They
may be due motor has demanded more
power than the RE can deliver. Assistance
goes to 0. Check the status of wiring or
decrease assist level.
SHORTCIRCUIT
223
Critical error of the RD. If the problem
persists, go to your dealer.
OPEN_CELL_WIRE
224
Failure in the internal wiring of the RE.
Assistance level goes to 0. If the problem
persists, go to your dealer.
IMBALANCE_SEVERAL_CELLS
225
Imbalance between RE cells. The capacity
of the RE may be limited. Perform a full
charge of the battery as soon as possible.
PACK_OVERTEMPERATURE
226
The temperature of the RE is too high.
Assistance goes to 0. Please cold down
the RE for better cell life.
PACK_UNDERTEMPERATURE
227
The temperature of the RE is too low.
Assistance goes to 0. The RD cells are
suffering a degradation from low
temperature. Please warm the RE for better
cell life.
PACK_OVERTEMPERATURE_ CHARGING
228
The temperature is too high to charge the
RE. Please go to a cooler place to charge.
PACK_UNDERTEMPERATURE_CHARGING
229
The temperature is too low to charge the
RE. Please go to a warmer place to charge.
OVERVOLTAGE_PROTECTION PACK
230
RE pack voltage is more than the max
allowed. Please stop charging the RE and
try to discharge it.
UNDERVOLGATE_PROTECTION_PACK
231
RE pack voltage is less than the minimum
allowed. It is recommended to charge the
battery as soon as possible.
OVERVOLTAGE_PROTECTION_PACK
232
Cell voltage of the RE is more than the max
allowed. Please stop the charging process
and try to discharge it.
UNERVOLTAGE_PROTECTION_CELL
233
RE pack voltage is higher than the
maximum allowed. It is recommended to
charge the battery as soon as possible.
FET_OVERTEMPERATURE
234
RE BMS MOSFET temperature failure. If
the problem persists, go to your dealer
with the RE.
FATAL_SOFTWARE_ERROR
238
Critical error of the RE. Assistance goes to
0. If the problem persists, replace the RE.
CAN_COMMUNICATION_ERROR
239
There are security errors in the RE
communications. Assistance goes to 0.
Avoid using NON MAHLE original
accessories.
240
POWER_OFF
241
BMS_COMM_ERROR
Internal error in the communication of
internal components of the BMS.
Assistance level goes to 0. If the problem
persists, replace the battery.
242
REVERSE_CURRENT
Reverse current error. Assistance goes to
0. Check the motor is not breaking the
eBike. If the problem persists, go to your
dealer.
Charger
Code
HMI
Description / Action
CHARGER_OVERTEMPERATURE
248
Charger overtemperature. Please go to a
cooler place to lower the temperature of
the charger.
CHARGER_SHORTCIRCUIT
249
Charger power error. Review the wiring.
Unplug and plug again the charger. If the
problem persists, please go to your dealer.
CHARGER_OVERVOLTAGE
250
Charger overvoltage. Unplug and plug
again the charger. If the problem persists,
go to your dealer.
CHARGER_OVERCURRENT
251
Charger overcurrent. Unplug and plug
again the charger. If the problem persists,
please go to your dealer.
252
CHARGER_TIMEOUT
Charger communication error. Unplug and
plug again the charger. If the problem
persists, go to your dealer.
253
CHARGER_CAN_COMMUNICATION
Charger communication error. Review the
connectors. Unplug and plug the charger. If
the problem persists, please go to your
dealer.
029