Descargar Imprimir esta página

Sanitizing Procedure - Manitowoc CNF201 Manual De Instalación, Operación Y Mantenimiento

Ocultar thumbs Ver también para CNF201:

Publicidad

Idiomas disponibles

Idiomas disponibles

Maintenance
Step 7
Remove the top cover from the ice chute and pour
the descaler/water solution into the evaporator. Add the
entire amount of premixed solution (excess solution will exit
through the overflow tube in the water reservoir).
Step 8
Replace the ice chute cover and allow the ice
machine to stand for 30 minutes.
Step 9
Turn on the water supply to the ice machine.
Step 10 Move the toggle switch to the ICE position. After
the 15 minute delay period expires, the compressor will
energize and produce ice with the descaling solution.
Step 11 The ice machine will freeze and discharge the
descaling solution into the bin. Allow the cycle to run for
15 minutes.
Step 12 Place the toggle switch in the OFF position and
refer to sanitizing procedure.
NOTE: Discard all ice produced during the descaling process.
Descaling and sanitizing must be performed on adjacent
surface areas not contacted by the water distribution system.
Refer to Component Disassembly for Descaling/Sanitizing
(page 19) - Disassemble, descale and sanitize the ice
machine a minimum of once every six months.

SANITIZING PROCEDURE

Ice machine sanitizer is used to remove algae or slime. It is
not used to remove lime scale or other mineral deposits.
Refer to the "Descaling Procedure" for removal of lime scale
or other mineral deposits.
NOTE: Sanitizing must be performed on adjacent surface
areas not contacted by the water distribution system. Always
perform Component Disassembly for Descaling/Sanitizing
procedure and a Descaling Procedure before sanitizing the
ice machine.
Step 1
Turn off the water supply to the ice machine.
Step 2
Place ICE/OFF/CLEAN toggle switch in the CLEAN
position. The dump valve will open and drain the water from
the evaporator and reservoir.
Step 3
Wait approximately 30 seconds (or until the
evaporator is drained) and place the toggle switch in the OFF
position.
Step 4
Refer to the chart and add the correct amount of
sanitizer and cool water for your model ice machine.
Model
Amount of Sanitizer
CNF201 CNF202
2 ounces (60 ml)
Step 5
Remove the top cover from the ice chute and pour
the sanitizer/water solution into the evaporator. Add the
entire amount of premixed solution (excess solution will exit
through the overflow tube in the water reservoir).
18
Step 6
machine to stand for 30 minutes.
Step 7
Step 8
the 15 minute delay period expires the compressor will
energize and produce ice with the sanitizing solution.
Step 9
sanitizing solution into the bin. Allow the cycle to run for
15 minutes.
NOTE: Discard all ice produced during the sanitizing process.
Step 10 Place the toggle switch in the CLEAN position. The
ice machine will run a wash cycle, a series of rinse cycles and
then stop. This entire cycle lasts approximately 30 minutes.
Step 11 Refer to Component Disassembly for Descaling/
Sanitizing (page 19), remove descal and sanitize all parts
listed.
Amount of Water
3 gallons (11 liters)
Replace the ice chute cover and allow the ice
Turn on the water supply to the ice machine.
Move the toggle switch to the ICE position. After
The ice machine will freeze and discharge the
Part Number: 000015202 Rev 01 07/22
Section 4

Publicidad

Solución de problemas

loading

Este manual también es adecuado para:

Cnf202