LEDS
DISPLAY
Is displayed on screen the instan-
O
taneous pressure in bar or psi
bar/psi
Pump ON and is displayed on
( ( O ) )
screen the instantaneous pressure
in bar or psi
Is displayed on screen the instan-
A
O
taneous current consumption in
(only
Ampere units
DGplus
Pump ON and is displayed on
and
( ( O ) )
screen the instantaneous current
DGM2)
consumption in Ampere units
O
Is displayed the start pressure
P START
( ( O ) )
Adjusting start pressure
Is displayed the stop pressure
O
(only in pressure dependent
MODE)
P STOP
Adjusting stop pressure
( ( O ) )
(only in pressure dependent
MODE)
FLOW
O
It indicates positive flow
Ratified dry-running or overload
O
alarms
ALARM
Dry-running alarm performing ART
( ( O ) )
or overload alarm preforming any
of the 4 restore attempts
P-BUT
TOUCH
TON
From state ON: any alarm is res-
tored.
From state OFF: system changes to
click!
STATE ON, the pump starts.
From any configuration MENU:
the parameter value is accepted.
From state ON: unit OFF, relay
disconnection.
HOLD
From state OFF: the pump starts
DOWN
and keeps operating until the
push-button is released.
Pstop is displayed on the screen for
click!
3 seconds.
Inside CONFIG or ADJUSTMENT
click!
modes is used to increase the para-
meters values.
3"
Pstop adjustment mode.
Pstart is displayed on the screen for
click!
3 seconds.
Inside CONFIG or ADJUSTMENT
click!
modes is used to dicrease the para-
meters values.
3"
Pstart adjustment mode.
Is displayed on the screen instanta-
neous current consumption.
click!
If it is already displayed then we
(only DG-
switch to instantaneous pressure
plus and
view.
DGM2)
3"
Rated current adjustment.
ACTION
ACTION
5
STARTUP (diagram C)
Before starting the device please read the pre-
vious sections, especially "Hydraulic Installation"
and "Electrical connection".
Follow next steps:
1. Start the device by pressing
2. (only DGplus and DGM2)
Set the pump rated current intensity value:
- Press
during 3 seconds.
- The current intensity value is displayed on screen
and LED A is flashing (factory setting 16A).
- By mean of
and
rrent reflected in the characteristics plate of the
motor. See Note 1.
- Press
for validation.
3. Set the cut-in (start) pressure:
- Press
during 3 seconds.
- The start pressure value is displayed on screen
and LED START is flashing.
- By mean of
and
re from 0,5 to 7 bar. *If it is higher than 3 bar, it
is advisable to use a small expansion tank.
- Press
for validation.
4. Set the cut-out pressure (only if it has been set on
ADVANCED MENU the pressure dependent operation
mode):
- Press
during 3 seconds.
- The stop pressure value is displayed on screen
and LED STOP is flashing.
- By mean of
and
re from 1 to 8 bar.
- Press
for validation.
In pressure dependent mode is compulsory the
installation of a pneumatic tank.
5. The unit is ready to operate but more optional
adjustments can be set through basic and advanced
MENUS. See the next chapter.
Note 1: it is important to introduce exactly the
rated current specified on the nameplate of the
pump. If a new pump is installed this process
should be repeated.

BASIC MENU

+
- Press simultaneously
- By mean of
or
- Press
for validation.
- This is the parameters sequence:
TYPE
SYSTEM REACTION
bar psi We can select the pressure units
displayed beetween bar and psi.
.
is adjusted the rated cu-
is adjusted the start pressu-
is adjusted the stop pressu-
(diagram C)
+
during 5 seconds.
the values can be changed.
FACTORY
SETTING
bar

Publicidad

loading

Este manual también es adecuado para:

Digimatic 2Digimatic 1