ADVANCED MENU

- Press simultaneously
conds.
- By mean of
or
- Press
for validation.
- The parameters sequence is:
TYPE
SYSTEM REACTION
Activation of the automatic restore
Ar0
Ar1
system ART (Ar1) o disable (Ar0).
In case of enabled ART, it can be
n01
n48
set the number of restore at-
tempts, between 1 and 48.
It can be set the span of the at-
t10
t40
tempt between 10 and 40 seconds.
Stand-by disabled (Sb0) or
Sb0
Sb1
enabled (Sb1)
It can be set a delay after reaching
dt0
dt9
the stop pressure from 1 to 9
seconds.
With PF=1 is activated the pressu-
PF0
PF1
re dependent mode with start and
stop pressures.
With P_ON is activated a mini-
mum operating pressure. Under
P0.0 P_ON
this pressure is activated an alarm
(A11).
Time, in seconds, under minimal
t05
t99
pressure necessary to activate A11.
(ONLY WITH PF1)
Fast-cycling alarm:
- rc0: alarm unabled.
- rc1: activated, when hammering
is detected it is delayed the
rc0
rc2
start in order to protect the
pump.
- rc2: alarm is activated and the
pump is stopped upon detec-
tion.
Only if fast-cycling alarm has been
activated in the previous step
(rc1&rc2). It can be choosed the
r01
r99
maximum time period between
3 consecutive starts that will be
considered fast cycling (between 1
sec. and 99 sec.)
Anti-flooding configuration.
If activated, it stops the pump
after programmed time (in hours)
H00
H99
of continuous operation.
Disabled (H00), 1 hour (H01) ... 24
hours (H24).
rs0
rs1
Restore factory settings (rs1)
ART FUNCTION (Automatic Reset Test)
When the device has stopped the pump by the
intervention of the dry-running protection system
(A01 ALARM) or minium pressure alarm (A11), the ART
tries, after 5 minutes, to re-start the pump in order to
restore the water supply.
After this first attempt are performed consecutive
attempts every 30 minutes.
This function can be activated in the ADVANCED
MENU. It can also be set the number of attempts (1-
48) and the span of the attempt (10-40 seconds).
+
+
+
+
during 5 se-
the values can be changed.
APR FUNCTION (Anti-blocking periodic routine)
After 72 hours without operation the pump is auto-
matically started for 10 seconds in order to avoid rotor
locking. Display will show the message "APr" while the
pump is operating.
REGISTER OPERATION DATA AND ALARMS
+
+
FAC-
TORY
SET-
- Press simultaneously
TING
conds.
- Press
to advance in the REGISTER.
Ar1
- The DATA sequence is:
48
MESSAGE
rEC
15"
HF xxx
HP xxx
0
CF xxx
0
Cr xxx
A01 xxx
0
A02 xxx
A04 xxx
0.0
A05 xxx
A11 xxx
APM xxx
20
rPM x.x
rSt
rc2

PRESSURE SENSOR CALIBRATION

In case of wrong lecture of the pressure sensor it can
be adjusted again.
For the pressure sensor calibration is necessary to
r03
have a pressure gauge in the installation. Proceed
following next steps:
ZERO REGULATION
1. Open the taps living the hydraulic net without
pressure.
2. Press simultaneously the buttons
H00
the display show 0.0 flashing.
3. Press
rs0
FULL SCALE
1. Start the pump until cut-out of the pressure switch.
2. Press simultaneously the buttons
display flashes with a figure.
3. Adjust the pressure with the arrows push-buttons
to get the pressure desired.
4. Press
Remark: pressure sensor decalibration should not
be a normal event. If it is frequently repeated con-
tact the technical service.
6
(only DGplus and DGM2)
+
+
DESCRIPTION
Controller operating hours
Pump operating hours
Operating cycles
Number of start-stop cycles.
Number of connections to the
power supply.
Number of A01 alarms.
Number of A02 alarms.
Number of A04 alarms.
Number of A05 alarms.
Number of A11 alarms.
Number of over-pressure
alarms (---).
Maximum registered pressure.
ENTER -> EXIT.
+
-> All the alarms are
restored except the opera-
tion data.
to validate.
to validate.
during 5 se-
SCOPE
0-65535
0-65535
0-999999
0-65535
0-999
0-999
0-999
0-999
0-999
0-999
and
until
and